High Speed Dome Camera User’s Manual
- 34 -
Vi d eo li ne
A lar m lin e
Co n tro l lin e/
Po wer line r
O
U
T2
GND
1
2
3
4
5
A+
B-
AC
24V
R
s485
6
7
A LA RMS
O
UT1
B NC
Figure 9
Alarm Input: Input signal of switch type, any other input signal will damage dome.
When multi-channel with alarm signal, dome will respond one by one, the removed time is two sec.
Once the dome have alarm input, dome will not respond “scanning” “patrol” “remember tracking” etc function.
Pin alarm input and output connection paraphrase:
7 Pin alarm input
2Pin alarm output
BLUE ALMIN COM AQUA ALMOUT- COM
PINK ALARM-1IN AZURY ALMOUT-1 NC
WHITE ALARM-2IN PURPLE ALMOUT-1NO
BLACK ALARM-3IN BROWN ALMOUT-2COM
RED ALARM-4IN GRAY ALMOUT-2NC
ORANGE ALARM-5IN SHIELD ALMOUT-2 NO
YELLOW ALARM-6IN
GREEN ALARM-7IN
11. Instruction of surface installation
:
According to the size of Dome's fixed board, drill the installation hole on the ceiling and fixed expander bolts(Also can drill hole
according to fixed hole of fixed board. Fix the fixed board, fix the main body of dome on fixed board along the guide pole, rotate the
Dome anticlockwise, tighten the screws(figure10)
Figure10