– 17 –
Outdoor unit pipe connection port
One unit of 1.8kW, 2.5kW or 3.5kW
One unit of 1.8kW, 2.5kW or 3.5kW
One unit of 1.8kW, 2.5kW, 3.5kW or 5.0kW
(5kW unit: Optional flare adaptor for piping is necessary)
Indoor unit 3
Indoor unit 2
Indoor unit 1
Dimension of Mounting Stand of
the Outdoor Unit
(Unit: mm)
Air blow
Mounting stand
Flare adaptor for piping
• ø9.52 (3/8") ø12.7 (1/2")
parts number TA261D-4 001
The flare adaptor for piping is
required depending on combination
of indoor units.
• Remove the side cover.
• For installation, refer as shown below.
• Install the unit in a stable place to minimize vibrationor noise.
Connecting the pipe
• After arranging the cord and pipes, secure them inplace.
Small diameter side service valve
Tightening torque:
13.7-18.6 N • m {140-190 kgf • cm}
• Hold the handle of the side cover. Slide down and takeoff
the corner hook, then pull. Reverse these stepswhen
installing.
Please face this side (suction side) of the unit to the wall.
Please remove side plate when connecting the piping
and connecting cord.
Slide lower
• The space indicated with a mark is required to guarantee the air conditioner's performance. Install the airconditioner in a
place big enough to provide ample space for servicing and repairs later on.
Heating efficiency will be increased if the ventilation below the outdoor unit is minimized.
507
10
(10)
320
340
198
12
37
57
above 700mm
above 200mm
(
)
above 100mm
above 100mm
Above 50mm when installed on the
ceiling of balcony.
Large diameter side service valve
Tightening torque:
34.3-44.1 N • m {350-450 kgf • cm}
MODEL: RAM-65QH5
Содержание RAM-55QH5
Страница 31: ... 30 CAPACITY DIAGRAM RELATED TO THE PIPING LENGTH MODEL RAM 65QH5 ...
Страница 37: ...CIRCUIT DIAGRAM MODEL RAM 55QH5 39 L C023 C022 C002 C001 C025 C024 N ...
Страница 38: ...CIRCUIT DIAGRAM MODEL RAM 65QH5 41 L C023 C022 C002 C001 C025 C024 N ...
Страница 41: ... 45 ...
Страница 46: ... 51 Outdoortemperature STAROTP_C TSKTM1_C1 Outdoortemperature STAROTP_C TSKTM1_C2 ...
Страница 47: ... 53 ...
Страница 48: ... 55 ...
Страница 49: ... 57 ...
Страница 50: ... 59 ...
Страница 68: ... 77 5A ...
Страница 75: ... 84 ...
Страница 76: ... 85 5 Reversing valve control circuit Fig 5 1 ...
Страница 79: ... 88 8 Overload control circuit OVL control circuit Fig 8 1 Overload Control System Configuration Fig 8 2 ...
Страница 91: ... 103 ...
Страница 92: ... 104 ...
Страница 98: ... 110 TROUBLESHOOTING OF THE SYSTEM POWER MODULE ...
Страница 99: ... 111 ...
Страница 100: ... 112 ...
Страница 102: ... 114 three three inlet 3 Cut off the three pipes at the side and bottom of Reversing valve ...
Страница 103: ... 115 ELECTRIC EXPANSION VALVE PIPE THERMISTOR POSITION CHARTS MODEL RAM 55QH5 MODEL RAM 65QH5 ...
Страница 108: ...HITACHI PM NO 0312E Printed in Malaysia RAM 55QH5 RAM 65QH5 ...