![Hitachi RAM-55QH5 Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/hitachi/ram-55qh5/ram-55qh5_service-manual_2139489014.webp)
– 13 –
TRIPLE SYSTEM MULTI R.A.C.
RAM-65QH5
CONNECTING POSISION TO BE ABLE TO INSTALL
POSSIBLE COMBINATIONS
TO INSTALL
(kW)
CONNECTING POSITION ON
OUTDOOR UNIT
(VALVE DIAMETER)
(mm)
No.1
No.2
SUITABLE ROOM SIZE
TO INSTALL
(m
2
)
No.3
6.35/9.52D
6.35/9.52D
6.35/9.52D
TWO UNITS
THREE UNITS
3.5+5.0
1.8+1.8+1.8
1.8+1.8+2.5
(11-14) + (16-18)
(8-12) + (8-12) + (8-12)
(8-12) + (8-12) + (11-17)
3.5
1.8
1.8
5.0
1.8
1.8
1.8
2.5
1.8+1.8
1.8+2.5
1.8+3.5
1.8+5.0
2.5+2.5
2.5+3.5
(8-12) + (8-12)
(8-12) + (10-16)
(7-9) + (15-22)
(6-9) + (18-27)
(12-15) + (12-15)
(11-14) + (14-18)
1.8
1.8
1.8
1.8
2.5
2.5
1.8
2.5
3.5
5.0
2.5
3.5
3.5+3.5
(13-16) + (13-16)
3.5
3.5
2.5+5.0
(10-12) + (18-20)
2.5
5.0
2.5, 3.5, 4.0, 5.0 means indoor units cooling capacity class.
(1) Marking
: needs flare adapter (9.52 12.7D): Part No. TA261D-4 001
(2) Suitable room size is determined based on the conditions below:
• Climate is in the temperate zone like Tokyo, Japan.
• For usual residential use.
• Smaller figure is for light construction which means light thermally sealed.
• Larger figure is for heavy constructions, which means well thermally sealed.
1.8+1.8+3.5
(7-11) + (7-11) + (14-21)
1.8
1.8
3.5
1.8+1.8+5.0
(5-8) + (5-8) + (16-25)
1.8
1.8
5.0
1.8+2.5+2.5
(7-11) + (10-15) + (10-15)
1.8
2.5
2.5
1.8+2.5+3.5
(6-10) + (9-13) + (12-19)
1.8
2.5
3.5
1.8+3.5+3.5
(5-8) + (11-17) + (11-17)
1.8
3.5
3.5
2.5+2.5+2.5
(10-11) + (10-11) + (10-11)
2.5
2.5
2.5
2.5+2.5+3.5
(8-10) + (8-10) + (12-12)
2.5
2.5
3.5
Содержание RAM-55QH5
Страница 31: ... 30 CAPACITY DIAGRAM RELATED TO THE PIPING LENGTH MODEL RAM 65QH5 ...
Страница 37: ...CIRCUIT DIAGRAM MODEL RAM 55QH5 39 L C023 C022 C002 C001 C025 C024 N ...
Страница 38: ...CIRCUIT DIAGRAM MODEL RAM 65QH5 41 L C023 C022 C002 C001 C025 C024 N ...
Страница 41: ... 45 ...
Страница 46: ... 51 Outdoortemperature STAROTP_C TSKTM1_C1 Outdoortemperature STAROTP_C TSKTM1_C2 ...
Страница 47: ... 53 ...
Страница 48: ... 55 ...
Страница 49: ... 57 ...
Страница 50: ... 59 ...
Страница 68: ... 77 5A ...
Страница 75: ... 84 ...
Страница 76: ... 85 5 Reversing valve control circuit Fig 5 1 ...
Страница 79: ... 88 8 Overload control circuit OVL control circuit Fig 8 1 Overload Control System Configuration Fig 8 2 ...
Страница 91: ... 103 ...
Страница 92: ... 104 ...
Страница 98: ... 110 TROUBLESHOOTING OF THE SYSTEM POWER MODULE ...
Страница 99: ... 111 ...
Страница 100: ... 112 ...
Страница 102: ... 114 three three inlet 3 Cut off the three pipes at the side and bottom of Reversing valve ...
Страница 103: ... 115 ELECTRIC EXPANSION VALVE PIPE THERMISTOR POSITION CHARTS MODEL RAM 55QH5 MODEL RAM 65QH5 ...
Страница 108: ...HITACHI PM NO 0312E Printed in Malaysia RAM 55QH5 RAM 65QH5 ...