– 58 –
6-7. Outdoor DC Fan Motor control circuit
This model uses DC Fan Motor which has a controller circuit built in the Motor.
This DC Fan Motor will rotate by control voltage apply to Vsp input. (V
(Voltage range: 1.7 to 7V DC)
Motor will output FG pulse by following this motor revolution.
indoor microcomputer.
This PWM control signal will convert to Vsp voltage by smoothing circuit. (R242 & C209)
rotation speed.
DC Fan Motor circuit has to match the Fan Motor revolution with instructed revolution. Such as...
FG feedback: Faster Instruction: Slower ... Decrease pulse width
FG feedback: Slower Instruction: Faster ... Increase pulse width
FG pulse is also used for Fan Motor failure detection.
Microcomputer will monitor FG pulse 30 seconds after start the fan motor. If there is no signal detected,
it will consider that the Fan Motor was malfunction and stop the operation. In this case, LD302 on main
R107 and IC4 are used for Fan Motor over current.
Vsp high : Faster ;
Vsp low : slower ;
Vsp lower than 1.7V
V
: stop
P.W.B. will blink 12 times. (Fan Motor lock detected)
FG pulse will feed back to Outdoor microcomputer 53 .
Outdoor microcomputer will output PWM control signal from 24 by following the instruction from
Fan motor will start to rotate when Vsp was proceeding over than 1.7V, and generate FG pulse by
1
24
53
46
45
44
HIC
Содержание RAC-E08H2
Страница 17: ... 15 CONSTRUCTION AND DIMENSIONAL DIAGRAM MODEL RAS E08H2A RAS E10H2A INDOOR UNIT Unit mm ...
Страница 18: ... 16 CONSTRUCTION AND DIMENSIONAL DIAGRAM MODEL RAC E08H2 RAC E10H2 OUTDOOR UNIT ...
Страница 22: ... 20 CIRCUIT DIAGRAM MODEL RAS E08H2A RAS E10H2A ...
Страница 23: ... 21 RAC E08H2 RAC E10H2 MODEL ...
Страница 25: ... 23 ...
Страница 27: ... 25 ...
Страница 28: ... 26 ...
Страница 30: ... 28 ...
Страница 31: ... 29 ...
Страница 47: ... 45 ...
Страница 48: ... 46 ...
Страница 50: ... 48 ...
Страница 51: ... 49 ...
Страница 52: ... 50 ...
Страница 54: ... 52 ...
Страница 71: ... 69 SELF DIAGNOSIS LIGHTING MODE MODEL RAC E10H2 SELF DIAGNOSIS LIGHTING MODE MODEL RAC E08H2 RAC E10H2 ...
Страница 77: ... 75 ...
Страница 81: ... 79 ...
Страница 82: ... 80 ...
Страница 83: ... 81 ...
Страница 92: ... 90 PARTS LIST AND DIAGRAM INDOOR UNIT MODEL RAS E08H2A RAS E10H2A ...
Страница 94: ...THE UPDATED PARTS LIST FOR THIS MODEL IS AVAILABLE ON ESTA ...
Страница 95: ...HITACHI RAS E08H2A RAC E08H2 RAS E10H2A RAC E10H2 SM0026 ...