![Hitachi RAC-70YH7 Скачать руководство пользователя страница 87](http://html.mh-extra.com/html/hitachi/rac-70yh7/rac-70yh7_service-manual_139754087.webp)
– 97 –
CHECKING THE REFRIGERATING CYCLE
1.
Troubleshooting procedure (No operation, No heating, No cooling)
Connect U,V,W phase leads to the
power module again and operate the
air conditioner.
Gas leaks.
Repair and seal refrigerant.
Is the self-diagnosis lamp mode as
shown on the right?
YES
Gas leaking
(less than 4kg/cm
2
G)
(less than 0.39 MPaG)
Normal
(0.39-0.98 MPaG)
(4-10 kg/cm
2
G)
Perform a final check of operation.
When the
self-diagnosis lamp
lights in the same
condition as above.
The compressor is defective. Replace it
and seal refrigerant.
If the compressor checker for an
inverter type air conditioner is
available, re-check using it.
( )
(JUDGING BETWEEN GAS LEAKAGE AND
COMPRESSOR DEFECTIVE)
Blinking
off
Time until the
lamp lights
Approx. 10 seconds
Approx.
10
seconds
Approx.
10
seconds
Within
Approx.
30
seconds
Compressor
Compressor
Gas
leakage
Possible
malfunctioning
part
LD301
Self-
diagnosis lamp
Lighting mode
Blinks
2 times
Blinks
3 times
Blinks
4 times
Blinks
5 times
Blinks
6 times
Blinks
8times
Stop to operate and check the gas
pressure in balancing mode.
Checking the system power module
Содержание RAC-70YH7
Страница 35: ... 35 CIRCUIT DIAGRAM Remote Control ...
Страница 36: ... 37 CIRCUIT DIAGRAM MODEL RAS 70YH7 ...
Страница 37: ... 39 CIRCUIT DIAGRAM MODEL RAC 70YH7 ...
Страница 39: ... 42 MODEL RAC 70YH7 P W B MAIN ...
Страница 40: ... 43 P W B IPM BOARD P W B NF BOARD ...
Страница 41: ... 44 BLOCK DIAGRAM MODEL RAS 70YH7 RAC 70YH7 1ø 50 60Hz 220 240V AX 8X10 FM Outdoor DC Fan Motor ...
Страница 42: ... 45 51 53 53 55 57 49 29 66 23 25 25 25 25 ...
Страница 46: ... 53 ...
Страница 56: ... 66 220 240 220 240 3 15A RAC 70YH7 ...
Страница 57: ... 67 AC220 240V DC260 360V ...
Страница 58: ... 68 C001 C007 C015 C016 C026 C027 L004 L005 J25 J25 J25 J23 J58 J25 ...
Страница 60: ... 70 ...
Страница 61: ... 71 ...
Страница 62: ... 72 3 15A Fuse ...
Страница 63: ... 73 3 15A 3 15A DC260 360V ...
Страница 66: ... 76 ...
Страница 67: ... 77 ...
Страница 68: ... 78 TROUBLE SHOOTING ...
Страница 69: ... 79 DISCHARGE PROCEDURE AND METHOD TO STOP ENERGIZE THE POWER CIRCUIT ...
Страница 70: ... 80 ...
Страница 75: ... 85 2 Outdoor unit does not operate but receives remote infrared signal ...
Страница 80: ... 90 AC220 240V AC240V P W Bs P W Bs Replace outdoor P W B Main P W Bs ...
Страница 81: ... 91 Replace outdoor P W B Main Replace fan motor Replace outdoor P W B Main ...
Страница 83: ... 93 ...
Страница 84: ... 94 ...
Страница 86: ... 96 CHECKING THE REMOTE CONTROLLER ...
Страница 92: ...PM NO 0465E Printed in Malaysia RAS 70YH7 RAC 70YH7 ...