TROUBLESHOOTING WHEN TIMER LAMP BLINKS.
Perform troubleshooting according to the number of times the indoor timer lamp and outdoor LD301 blink.
SELF-DIAGNOSIS LIGHTING MODE
No.
Blinking of Timer lamp
Reason for indication
Possible cause
Reversing valve defective
When the indoor heat exchanger
temperature is too low in the
heating mode or it is too high in the
cooling mode.
Outdoor unit forced operation
When the outdoor unit is in forced
operation or balancing operation
after forced operation
Indoor/outdoor interface defective
When the interface signal from the
outdoor unit is interrupted.
Outdoor electrical assembly
defective.
Room thermistor or heat exchanger
thermistor is faulty
When room thermistor or heat
exchanger thermistor is opened
circuit or short circuit.
Over-current detection at the DC fan
motor
when over-current is detected at the
DC fan motor of the indoor unit.
IC401 or IC402 data reading error
When data read from IC401 or
IC402 is incorrect.
(1) Reversing valve defective
(2) Heat exchanger thermistor dis-
connected
(only in the heating mode)
(Note)
The malfunction mode is entered the
3rd time this abnormal indication
appears (read every 3 minutes).
Electrical parts in the outdoor unit
(1) Indoor interface circuit
(2) Outdoor interface circuit
Please check at the outdoor
electrical led lamp blinking (LD301)
and refer to self diagnosis lighting
mode for outdoor unit.
(1) Room thermistor
(2) Heat exchanger thermistor
(1) Indoor fan locked
(2) Indoor fan motor
(3) Indoor control P.W.B.
IC401 or IC402 abnormal
<Cautions>
(1)
If the interface circuit is faulty when power is supplied, the self-diagnosis display will not be displayed.
(2)
If the indoor unit does not operate at all, check to see if the F-cable is connected or disconnected.
(3)
To check operation again when the timer lamp is blinking, you can use the remote control for operation
(except for mode mark 1).
1
2
3
4
5
6
7
( – – Lights for 0.5 sec. at interval of 0.5 sec..)
– – 10 times
– – – – – – 3 times
– – – – – – – – 1 time
– – – – – – – 2 times
– – 13 times
1
– – 9 times
– – 4 times
5 sec.
5 sec.
5 sec.
5 sec.
5 sec.
5 sec.
5 sec.
5 sec.
Содержание RAC-70YH7
Страница 35: ... 35 CIRCUIT DIAGRAM Remote Control ...
Страница 36: ... 37 CIRCUIT DIAGRAM MODEL RAS 70YH7 ...
Страница 37: ... 39 CIRCUIT DIAGRAM MODEL RAC 70YH7 ...
Страница 39: ... 42 MODEL RAC 70YH7 P W B MAIN ...
Страница 40: ... 43 P W B IPM BOARD P W B NF BOARD ...
Страница 41: ... 44 BLOCK DIAGRAM MODEL RAS 70YH7 RAC 70YH7 1ø 50 60Hz 220 240V AX 8X10 FM Outdoor DC Fan Motor ...
Страница 42: ... 45 51 53 53 55 57 49 29 66 23 25 25 25 25 ...
Страница 46: ... 53 ...
Страница 56: ... 66 220 240 220 240 3 15A RAC 70YH7 ...
Страница 57: ... 67 AC220 240V DC260 360V ...
Страница 58: ... 68 C001 C007 C015 C016 C026 C027 L004 L005 J25 J25 J25 J23 J58 J25 ...
Страница 60: ... 70 ...
Страница 61: ... 71 ...
Страница 62: ... 72 3 15A Fuse ...
Страница 63: ... 73 3 15A 3 15A DC260 360V ...
Страница 66: ... 76 ...
Страница 67: ... 77 ...
Страница 68: ... 78 TROUBLE SHOOTING ...
Страница 69: ... 79 DISCHARGE PROCEDURE AND METHOD TO STOP ENERGIZE THE POWER CIRCUIT ...
Страница 70: ... 80 ...
Страница 75: ... 85 2 Outdoor unit does not operate but receives remote infrared signal ...
Страница 80: ... 90 AC220 240V AC240V P W Bs P W Bs Replace outdoor P W B Main P W Bs ...
Страница 81: ... 91 Replace outdoor P W B Main Replace fan motor Replace outdoor P W B Main ...
Страница 83: ... 93 ...
Страница 84: ... 94 ...
Страница 86: ... 96 CHECKING THE REMOTE CONTROLLER ...
Страница 92: ...PM NO 0465E Printed in Malaysia RAS 70YH7 RAC 70YH7 ...