![Hitachi RAC-50FPA Скачать руководство пользователя страница 52](http://html.mh-extra.com/html/hitachi/rac-50fpa/rac-50fpa_service-manual_139703052.webp)
Fig. 1-1
Power to operate indoor unit (DC35V) is generated at the power supply in outdoor unit and it is sent to indoor unit
through the connecting cord C and D.
Then, DC 12V (12V line) is generated using DC/DC converter from the voltage sent from outdoor unit, as the
control voltage of 12V is required to drive the auto sweep motor and others.
Furthermore, 5V (5V line), which is necessary to drive the microcomputer and to control the fan motor, is generated
using three-terminal regulator IC121.
1. Power circuit
DESCRIPTION OF MAIN CIRCUIT OPERATION
RAF-50RPA
C133
Q111
R114
Q113
Q112
R1
1
1
R115
C1
13
C1
16
R1
12
ZD1
1
1
R1
16
R1
17
C1
1
1
Q116
R124
R121
R122
R123
Q115
C1
12
IC111
8
L751
R631
L752
R752
C132
ZD131
M
CN10
1
2
3
4
5
6
C131
C751
C621
R751
Motor
Indoor Fan
IN
OUT
GND
D121
-
0V
+
ZD121
R1
18
C103
35V
35V
0V
ICP2
C1
15
L111
C1
14
D1
1
1
R1
19
ICP1
-
-
+
C102
+
12V
5V
0V
5V
C121
IC121
C123
C122
R125
R126
XA-6P-Top
R131
R132
Q131
CJ2
R120
Q114
Q751
47
97
57
45
7
10
68
IC712
7
6
1
4
3
2
5
12 V power supply
Power supply voltage
Indoor fan power supply
Indoor fan PWM output
Indoor fan speed feedback
52
Содержание RAC-50FPA
Страница 2: ...DANGER 2 ...
Страница 32: ...WIRING DIAGRAM OF THE PRINTED WIRING BOARD 2 E 5 R A R r e l l o r t n o c e t o m e R 32 ...
Страница 33: ...A P R 0 5 F A R L E D O M 33 ...
Страница 34: ...MODEL RAC 50FPA 34 ...
Страница 39: ...39 ...
Страница 41: ...41 ...
Страница 44: ...44 ...
Страница 46: ...RAF 50RPA RAC 50FPA COOLING CYCLE INDOOR UNIT OUTDOOR UNIT HEATING CYCLE INDOOR UNIT OUTDOOR UNIT 46 ...
Страница 57: ...10 10 10 10 R921 R924 R642 R544 R542 R610 R922 DSW1 DSW1 R923 R541 R543 57 93 ...
Страница 59: ... 9 9 RQWURO 3 0LFURFRPSXWHU 59 ...
Страница 60: ... TEST SWI TCH SW SEL F CHECK L A N B C D 3 RQWURO 5HDFWRU FRQQHFWRU 30 3 30 6PRRWKLQJ DSDFLWRU 60 ...
Страница 62: ...62 ...
Страница 63: ...5 Electric expansion valve circuit 22 23 24 25 12 13 14 15 5 4 3 2 34 32 30 29 RED 63 ...
Страница 64: ...3 15A Fuse Switching power source 64 ...
Страница 65: ...3 15A 3 15A DC260 360V 65 ...
Страница 72: ...7528 6 227 1 RA 50FPA C 72 ...
Страница 74: ...74 ...
Страница 75: ...7528 6 227 1 1 7 7 0 5 03 1 6 1 0 1 1 2 RAF 50RPA 7 75 ...
Страница 77: ...77 78 ...
Страница 78: ...78 ...
Страница 85: ... 1 7 287 225 81 7 75 3 576 MODEL RAC 50FPA 85 ...
Страница 87: ...9 V 3 V 3 Q L D 0 3 U R R G W X R H F D O S H 5 V 3 9 87 ...
Страница 88: ... Q L D 0 3 U R R G W X R H F D O S H 5 U R W R P Q D I H F D O S H 5 Q L D 0 3 U R R G W X R H F D O S H 5 88 ...
Страница 90: ... 1 7 5 027 21752 5 90 ...
Страница 91: ...91 36 ...
Страница 92: ...Please set the DIP switch No 6 to ON accordingly Refe to page 57 r 92 ...
Страница 93: ...93 57 ...
Страница 94: ...94 ...
Страница 97: ...38 39 PARTS LIST AND DIAGRAM INDOOR UNIT MODEL RAF 50RPA 97 ...
Страница 98: ...MODEL RAF 50RPA 98 HWRAF 50NX2 A14 HBOARD AS ...
Страница 99: ...30 OUTDOOR UNIT MODEL RAC 50FPA 99 ...
Страница 101: ...NO 0070E RAF 50RPA RAC 50FPA HHAW 101 2 ...