  THIS APPLIANCE MUST BE EARTHED.

Wiring Of The Indoor Unit

(1)  Remove the cover of the electric box.
(2)  Connect the connecting cords.
(3)  Assemble the cover of electric box.

Procedures of Wiring

CONNECTION OF POWER CORD

WARNING

!

Power supply shall be connected at the rated voltage, otherwise the unit will be broken or could 
not reach the speci ed capacity.

Checking for the electric source and 
the voltage range

O

 Before installation, the power source must be checked and necessary 

wiring work must be completed. To make the wiring capacity proper, 
use the wire gauge list below for the wiring from a switch board of fuse 
box to the outdoor unit in consideration of the locked rotor current.

IMPORTANT

O

 The naked part of the wire core should be 10 mm and  x it to the terminal tightly. Then try 

to pull the individual wire to check if the contact is tight. Improper insertion may burn the 
terminal.

O

 Be sure to use only power cables approved from the authorities in your country. For example 

in Germany: Cable type: NYM 3x1.5mm

2

. (Fuse = 20A time delay)

O

 Please refer to the installation manual for wire connection to the terminals of the units. The 

cabling must meet the standards of electrical installation.

O

 There is a AC voltage of 220-240V between the L and N terminals (indoor unit) and 380V 

between R,S,T,N terminals (outdoor unit). Therefore, before servicing, be sure to remove the 
power cord from the AC outlet or switch off the main switch.

O

 Do not make any connection in the middle of the connecting power cord. It may cause the 

wire over heated, emit smoke and  re.

WARNING

!

WARNING

O

 If you cannot attach the side cover due to the 

connecting cord, press the connecting cord in direction 
to the front panel to  x it.

O

 Be sure that the hooks of the side cover is  xed in 

certainly. Otherwise water leakage may occur and 
this causes short circuit or faults.

O

 The connecting cord should not touch to service 

valve and pipes. (It becomes high temperature in 
heating operation.)

O

  Investigate the power supply capacity and other electrical conditions 

at the installation location.

  Depending on the model of room air conditioner to be installed, 

request the customer to make arrangements for the necessary 
electrical work etc.

  The electrical work includes the wiring work up the outlet. In localities 

where electrical conditions are poor, use of a voltage regulation is 
recommended.

Wiring Of The Outdoor Unit

O

 Please remove the side cover for wire connection.

!

Cable length

up to 15m

up to 25m

Wire cross-section

2.5mm

2

4.0mm

2

IMPORTANT

Fuse Capacity

20A time delay fuse

FINAL

 ST

AGE OF INST

ALLA

TION

Insulation And Maintenance Of Pipe Connection

1

O

 The connected terminals should be completed sealed with 

heat insulator and then tied up with rubber strap.

O

 Please tie the pipe and power line together with vinyl tape 

as shown in the  gure showing the installation of Indoor and 
Outdoor units. Then  x their position with holders.

O

 To enchance the heat insulation and to prevent water 

condensation, please cover the outdoor part of the drain hose 
and pipe with insulation pipe.

O

 If room humidity is high, cover the connecting pipe with 

additional 5mm thickness insulator. This insulator shall be 
purchased from  eld.

O

 Completely seal any gap with putty.

  Power Source And Operation Test

2

Power Source

Operation Test

O

  Please ensure that the air conditioner is in normal operating 

condition during the operation test.

O

 Explain to your customer the proper operation procedures 

as described in the user’s manual.

  Installation Of Air Panel

3

O

 Carefully read through the procedures of proper installation 

before starting installation work.

CAUTION

!

O

 Please use a new socket. Accident may occur due to the 

use of old socket because of poor contact.

O

 Please plug in and then remove the plug for 2 – 3 times. 

This is to ensure that the plug is completely plugged into 
the socket.

O

 Keep additional length for the power cord and do not 

render the plug under external force as this may cause 
poor contact.

O

 Do not  x the power cord with U-shape nail.

Connect the 
earth cord

Insert and  x the connecting cords 
with screws (3 places)

Insert and  x 
the connecting 
cords with screw 
(5 places)

Connect the 
earth cord

Loose the band, put the 
connecting cords in the 
band and snap it.

Loose the band, put the 
connecting cords in the 
band and snap it.

Connecting cords

Removal Of Air From The Pipe And Gas Leakage Inspection

Gas Leakage Inspection

Please use gas leakage detector to check if leakage 
occurs at the connection of Flare nut as shown on the 
right.

If gas leakage occurs, further tighten the connection to 
stop leakage. 

Procedures of using Vacuum Pump for Air Removal

As shown in  gure on the right, remove 
the cap of valve head and valve core 
and then connect them to the vacuum 
pump and manifold valve.

Fully tighten the “Hi” shuttle of the 
manifold valve and completely unscrew 
the “Lo” shuttle. Run the vacuum pump 
for about 10–15 minutes, then completely 
tighten the “Lo” shuttle and switch off the 
vacuum pump.

2

Completely unscrew the spindle of 
the service valve (at 2 places) in anti-
clockwise direction to allow the  ow  of 
coolant (using Hexagonal Wrench key).

3

Remove the Charge hose and tighten 
the cap of valve head. The task is then 
completed.

4

1

1

O

 Use a pipe cutter to cut the copper pipe.

O

 Jagged edge will cause leakage.

O

 Point the side to be trimmed downwards during trimming to prevent copper chips 

from entering the pipe.

O

 Before  aring, please insert the  are nut into the pipe.

   Pipe Connection

2

INST

ALLA

TION OF REFRIGERA

TING PIPES 

AND 

AIR REMOV

AL

CAUTION

!

AIR REMOV

AL

CAUTION

!

In case of removing Flare nut of a indoor unit,  rst remove a nut of 
small diameter side, or a seal cap of big diameter side will  y out.

O

 Please be careful when bending the copper pipe.

O

 Applied frozen grease to the connection points and then screw in manually. After 

that, use a torque wrench to tighten the connection.

 Please mount the outdoor 

u n i t   o n   s t a b l e   g r o u n d 
to prevent vibration and 
increase of noise level.

  Decide the location for piping 

after sorting out the different 
types of pipe available.

 Open the side plate by 

unscrewing the screws as 
shown below.

Please face this side 
(suction side) of the 
unit to the wall.

Please 
remove side 
cover when 
connecting 
the piping 
and 
connecting 
cord.

CAUTION

!

Please make sure to remove 

all spacers inside the unit.

 Open the Top, Back and 

Side cover of the unit.

 Pull out the spacers inside.

  ( S p a c e r s   a r e   o n l y   f o r 

transportation purpose).

  If not remove, vibration and 

noise will occur.

Top cover

CONDENSED WATER DISPOSAL OF OUTDOOR UNIT

 

There are holes on the base of Outdoor unit for condensed water 
to exhaust.

  In order to  ow condensed water to the drain, the unit is installed 

on a stand or a block so that the unit is 100mm above the ground 
as shown  gure. Join the drain pipe to one hole.

  At  rst insert one portion of the hook to the base (Portion A), then 

pull the drain pipe in the direction shown by the arrow while inserting 
the hook into the base. After installation, check whether the drain 
pipe cling to the base  rmly.

  When using in cold region, etc.

  In cold region with severe cold climate and heavy snow, water 

discharged from heat exchanger freeze on the base surface and this 
may affect drainage. In such a region, remove bush on the bottom 
face of outdoor unit for better drainage. When using drainpipe, 
consult our dealer.

Side cover

Back cover

3

   Preparation of Pipe

Outer

dia.of pipe

6.35 (1/4")

15.88 (5/8")

6.35 (1/4")

15.88 (5/8")

Valve 

head cap

Torque N·m

(kgf 

·

 cm)

13.7 – 18.6 (140 – 190)

49.0 – 58.8 (500 – 600)

19.6 – 24.5 (200 ~ 250)

29.0 – 31.0 (296 ~ 316)

12.3 – 15.7 (125 ~ 160)

Small dia. side

Large dia. side

Valve core cap

Small dia. side

Large dia. side

When the meter reaches - 101KPa 
(-76cmHg) during pumping, fully 
tighten the shuttle.

When pumping starts, slightly loosen the 
 are nut to check of air sucked in. Then 
tighten the  are nut.

Lo

Hi

Meter showing pressure

Manifold valve

Vacuum 
pump

Valve

Valve

Charge hose

Vacuum pump
adapter

Outer
Diameter (mm)

6.35

15.88

Imperial  aring tool

0.8 

~

 1.5mm

1.0 

~

 2.0mm

Rigid  aring tool

A (mm)

~

 0.5mm

~

 1.0mm

Pull 
downward

DRAIN PIPE

BASE

OUTDOOR UNIT

BUSH

BUSH

DRAIN PIPE

100 mm 

ABOVE

Flare nut

Torque
wrench

Wrench

Die

Copper pipe

Die

Copper pipe

Trimming tool

The body of
service valve

Cap of
valve core

Cap of valve head

Cap of valve head

Hexagonal
Wrench Key

Terminal Board

Green & Yellow

Terminal Board

Brown

Blue

Green &

Yellow

Green & Yellow

Connecting Cord

Outdoor Unit

3ø Phase
Power Cable

Indoor Unit

Power Cord

Power Cable

Strip wires

GRN + YEL

Strip wires

GRN + YEL

Outdoor Unit

Indoor Unit

Insulation material for pipe connection

Sleeve of
protection pipe

Putty

(EN) INS RCI-30MH1 (4).indd   4

7/19/10   11:33 AM

Содержание RAC-30MH1

Страница 1: ...circuit breaker or fuse the danger of electric shock exists A main switch with a contact gap of more than 3 5mm has to be installed in the power supply line to the outdoor unit O Piping shall be suitable supported with a maximum spacing of 1m between the supports O Do not install the unit near a location where there is ammable gas The outdoor unit may catch re if ammable gas leaks around it O For ...

Страница 2: ...e drain piping pour another 1 5 to 2 0 liters of water into the drain D Switch ON the power supply and press the RUN STOP button CAUTION O In case of pouring water through the access door O In case of pouring water through the air outlet 1 The position of the drain pipe connection is shown in Fig 6 1 Fig 6 1 Position of Drain Pipe Connection 2 Prepare a polyvinyl chloride pipe with a 32mm outer di...

Страница 3: ...nnector Wall recessed wiring installation Supplied 0 50 gap Inside top wiring installation Alternative Wires Wires Lead wires 3 strands Lead wires connector Wiring installation illustrations When the wires to be connected from the inside top portion of top casing 1 Break off a perforated aperture located at the top portion of the bottom casing by nipper Smoothen the aperture by cutter 2 Fix the bo...

Страница 4: ...the band put the connecting cords in the band and snap it Loose the band put the connecting cords in the band and snap it Connecting cords Removal Of Air From The Pipe And Gas Leakage Inspection Gas Leakage Inspection Please use gas leakage detector to check if leakage occurs at the connection of Flare nut as shown on the right If gas leakage occurs further tighten the connection to stop leakage P...

Отзывы: