Hitachi RAC-30MH1 Скачать руководство пользователя страница 3

 

O

 

The remote controller can be placed in its holder which             
is  xed on wall  or beam.

 

O

 

To operate the remote controller at its holder, please           
ensure that the unit can receive signal transmitted from   
the controller at the place where the holder is to be  xed. 
The unit will beep when signal is 

 

  received from the remote controller. 

 

  The signal transmission is weaken 

 

  by the  uorescent light. Therefore, 

 

  during the installation of the remote 

 

  control holder, please switch on the 

 

  light, even during day time, to 

 

  determine the mounting location of

  

the 

holder.

Installation of wireless remote controller (optional)

When connecting the HA System/H-Link

Setting of Installation Level Switch

8

9

10

The controller must 
be hooked onto the 
hook at the lower 
part of the holder. 
Push in the remote 
controller in the 
direction as shown 
in  gure  below.

Connection of display panel lead wires (Optional)

O

 

Attach the connector of this panel to the connector CN11 on the control PWB.

     (Refer diagram below)

O

 

A separately purchased HA Connection Cord (Service part component part number (RAS-N22V100)] is required to 
get connect to the HA-System.

O

 As for connecting to H-Link, a separately purchased RAC adapter is required.

O

 To install the wiring, the electrical box cover must be opened. (As for HA-System, connect to CN9 whereas for the 

RAC adapter, connect to CN18).

O

 The connection cord and power cables are to be arranged and tied up as per the diagram as shown below.

O

 Please refer to the respective user manuals of the H-System and the RAC adapter, for further details.

O

 Please refer to the user manual for instructions on the removal and installation of the electrical box.

Selecting the switch

O

 Turn power off.

O

 Remove cover of the electrical box.

O

 When install the indoor unit higher than 3.0 meter from the  oor, select the “INST LEVEL SW” on the main PWB to 

HIGH.

O

 When install the indoor unit between 2.3 meter to 3.0 meter from the  oor, select the “INST LEVEL SW” on the main 

PWB to NORMAL.

Installation of wired remote controller

7

 

When connecting the wires via the wall’s recessed slot;

1. Fix the bottom casing to the wall by provided screw.
2. Assemble the top casing to the  xed bottom casing.
  (Refer to the illustration below for detail installation)

Lead wires (3 strands) 
are inserted through and 
fastened via a rib-clip

Location of wall 
mounting screw

Lead wires
connector

Wires

Wires

Lead wires 
connector

Wall recessed wiring installation (Supplied)

0.50 gap

Inside top wiring installation (Alternative)

Wires

Wires

Lead wires 
(3 strands)

Lead wires 
connector

Wiring installation illustrations

 

When the wires to be connected from the inside top portion of top casing;

1. Break off a perforated aperture located at the top portion of the bottom         

casing by nipper. Smoothen the aperture by cutter.

2. Fix the bottom casing to the wall by provided screw.
3. Connect the wires to the lead wires connector.
4. Mount the wires through the provided slot on top casing.
5. Assemble the top casing to the  xed bottom casing
  (Refer to the illustration below for detail installation)

Wall
mounting 
screws 
(2 pieces)

15  

W

all mounting screws (2 pieces to be used)

(a) Connection to the electrical box;
   

O

  Remove the cover of electric box 

 

O

  Connect the connector of wired remote controller to CN17

   

O

  Assemble back the cover of electrical box

(b) Wiring installation for wired remote controller (2 mehtods);
   

O

  Wired remote controller casing can be opened by pressing the slots with minus screw driver (see below diagram)

 

Wired remote controller

Remote 
controller

Top casing

Bottom casing

O

 Decide the  xing location of remote controller so that the length of wire shall be within 5 meters.

O

 Do not cut the provided wire. Excess wire should be properly wound and  tted at safe place.

O

 Do not join the wire with additional wire.

Installation of display panel (Optional)

 

O

 Select an installation position on ceiling or wall where there 

is no obstacle to interrupt signal reception.

O

 Loosen screws of panel installation plate so that bracket 

can be slightly moved.

O

 Match the display panel to panel installation plate so the 

 xing claws on the panel are securely hooked.

O

 Match brackets to the opening on ceiling or wall and tighten 

screws until bracket is  rmly secured to ceiling material.

O

 Install the panel cover so inside claws are securely hooked 

to the panel installation plate.

O

 Conduct the indoor unit side housing of display panel cord 

to the electric box of the indoor unit and connect it with 
the housing at the side of the unit.

Please disconnect wired remote controller 
connector at CN17 if to use wireless remote 
controller.

Opening on ceiling or wall

Display panel

Claw

Screw

Panel Installation plate

Panel cover

Bracket

CROSS SECTION

Bracket

Display panel

Bracket

Panel cover

Ceiling or wall 
(Thickness 7~18mm)

Above

50mm

Display panel cord

Connection cords

Binder

INST

LEVEL

SW

NORMAL

HIGH

Plug

AAA

size

battery

CAUTION

CAUTION

Screw (2 pieces)

Holder for
Remote Controller

Remote Controller

<

IA669: A 

>

(EN) INS RCI-30MH1 (4).indd   3

7/19/10   11:33 AM

Содержание RAC-30MH1

Страница 1: ...circuit breaker or fuse the danger of electric shock exists A main switch with a contact gap of more than 3 5mm has to be installed in the power supply line to the outdoor unit O Piping shall be suitable supported with a maximum spacing of 1m between the supports O Do not install the unit near a location where there is ammable gas The outdoor unit may catch re if ammable gas leaks around it O For ...

Страница 2: ...e drain piping pour another 1 5 to 2 0 liters of water into the drain D Switch ON the power supply and press the RUN STOP button CAUTION O In case of pouring water through the access door O In case of pouring water through the air outlet 1 The position of the drain pipe connection is shown in Fig 6 1 Fig 6 1 Position of Drain Pipe Connection 2 Prepare a polyvinyl chloride pipe with a 32mm outer di...

Страница 3: ...nnector Wall recessed wiring installation Supplied 0 50 gap Inside top wiring installation Alternative Wires Wires Lead wires 3 strands Lead wires connector Wiring installation illustrations When the wires to be connected from the inside top portion of top casing 1 Break off a perforated aperture located at the top portion of the bottom casing by nipper Smoothen the aperture by cutter 2 Fix the bo...

Страница 4: ...the band put the connecting cords in the band and snap it Loose the band put the connecting cords in the band and snap it Connecting cords Removal Of Air From The Pipe And Gas Leakage Inspection Gas Leakage Inspection Please use gas leakage detector to check if leakage occurs at the connection of Flare nut as shown on the right If gas leakage occurs further tighten the connection to stop leakage P...