O
The remote controller can be placed in its holder which
is xed on wall or beam.
O
To operate the remote controller at its holder, please
ensure that the unit can receive signal transmitted from
the controller at the place where the holder is to be xed.
The unit will beep when signal is
received from the remote controller.
The signal transmission is weaken
by the uorescent light. Therefore,
during the installation of the remote
control holder, please switch on the
light, even during day time, to
determine the mounting location of
the
holder.
Installation of wireless remote controller (optional)
When connecting the HA System/H-Link
Setting of Installation Level Switch
8
9
10
The controller must
be hooked onto the
hook at the lower
part of the holder.
Push in the remote
controller in the
direction as shown
in gure below.
Connection of display panel lead wires (Optional)
O
Attach the connector of this panel to the connector CN11 on the control PWB.
(Refer diagram below)
O
A separately purchased HA Connection Cord (Service part component part number (RAS-N22V100)] is required to
get connect to the HA-System.
O
As for connecting to H-Link, a separately purchased RAC adapter is required.
O
To install the wiring, the electrical box cover must be opened. (As for HA-System, connect to CN9 whereas for the
RAC adapter, connect to CN18).
O
The connection cord and power cables are to be arranged and tied up as per the diagram as shown below.
O
Please refer to the respective user manuals of the H-System and the RAC adapter, for further details.
O
Please refer to the user manual for instructions on the removal and installation of the electrical box.
Selecting the switch
O
Turn power off.
O
Remove cover of the electrical box.
O
When install the indoor unit higher than 3.0 meter from the oor, select the “INST LEVEL SW” on the main PWB to
HIGH.
O
When install the indoor unit between 2.3 meter to 3.0 meter from the oor, select the “INST LEVEL SW” on the main
PWB to NORMAL.
Installation of wired remote controller
7
When connecting the wires via the wall’s recessed slot;
1. Fix the bottom casing to the wall by provided screw.
2. Assemble the top casing to the xed bottom casing.
(Refer to the illustration below for detail installation)
Lead wires (3 strands)
are inserted through and
fastened via a rib-clip
Location of wall
mounting screw
Lead wires
connector
Wires
Wires
Lead wires
connector
Wall recessed wiring installation (Supplied)
0.50 gap
Inside top wiring installation (Alternative)
Wires
Wires
Lead wires
(3 strands)
Lead wires
connector
Wiring installation illustrations
When the wires to be connected from the inside top portion of top casing;
1. Break off a perforated aperture located at the top portion of the bottom
casing by nipper. Smoothen the aperture by cutter.
2. Fix the bottom casing to the wall by provided screw.
3. Connect the wires to the lead wires connector.
4. Mount the wires through the provided slot on top casing.
5. Assemble the top casing to the xed bottom casing
(Refer to the illustration below for detail installation)
Wall
mounting
screws
(2 pieces)
15
W
all mounting screws (2 pieces to be used)
(a) Connection to the electrical box;
O
Remove the cover of electric box
O
Connect the connector of wired remote controller to CN17
O
Assemble back the cover of electrical box
(b) Wiring installation for wired remote controller (2 mehtods);
O
Wired remote controller casing can be opened by pressing the slots with minus screw driver (see below diagram)
Wired remote controller
Remote
controller
Top casing
Bottom casing
O
Decide the xing location of remote controller so that the length of wire shall be within 5 meters.
O
Do not cut the provided wire. Excess wire should be properly wound and tted at safe place.
O
Do not join the wire with additional wire.
Installation of display panel (Optional)
O
Select an installation position on ceiling or wall where there
is no obstacle to interrupt signal reception.
O
Loosen screws of panel installation plate so that bracket
can be slightly moved.
O
Match the display panel to panel installation plate so the
xing claws on the panel are securely hooked.
O
Match brackets to the opening on ceiling or wall and tighten
screws until bracket is rmly secured to ceiling material.
O
Install the panel cover so inside claws are securely hooked
to the panel installation plate.
O
Conduct the indoor unit side housing of display panel cord
to the electric box of the indoor unit and connect it with
the housing at the side of the unit.
Please disconnect wired remote controller
connector at CN17 if to use wireless remote
controller.
Opening on ceiling or wall
Display panel
Claw
Screw
Panel Installation plate
Panel cover
Bracket
CROSS SECTION
Bracket
Display panel
Bracket
Panel cover
Ceiling or wall
(Thickness 7~18mm)
Above
50mm
Display panel cord
Connection cords
Binder
INST
LEVEL
SW
NORMAL
HIGH
Plug
AAA
size
battery
CAUTION
CAUTION
Screw (2 pieces)
Holder for
Remote Controller
Remote Controller
<
IA669: A
>
(EN) INS RCI-30MH1 (4).indd 3
7/19/10 11:33 AM