– 188 –
Communication error
.
LD301 b
links 9 times
.
Is the connecting cab
le
connected proper
ly?
(Is 35V being output on the
indoor unit side?)
Are CN3 and CN4
connected?
Is DC35V being output
between ter
minals C and D?
Nor
mal:
DC32V – 39V
Is DC35V being output at
both ends of R35?
Connect CN 3 and CN4.
Connect proper
ly
.
Replace the po
wer
P.
W
.B
.
• Def
ectiv
e SW po
wer supply
Replace the po
wer
P.
W
.B
.
• NF coils
, IF coils
, etc.
ma
y be brok
e
n.
Chec
k the interf
ace circuit
and replace the main
P.
W
.B
. if needed.
Ye
s
Ye
s
Ye
s
Ye
s
Y
e
s
No
No
No
No
No