– 11 –
ENGLISH
FAN SPEED (AUTO)
..... When the AUTO fan speed mode is set in the cooling/heating operation:
For the heating operation
The fan speed will automatically change according to the temperature
of discharged air.
When the difference of room temperature and setting temperature is
large, fan starts to run at HI speed.
When the room temperature reaches setting temperature, fan speed
changes to LOW automatically.
When the difference of room temperature and setting temperature is
large, fan starts to run at HI speed.
After room temperature reaches the preset temperature, the cooling
operation, which changes the fan speed and room temperature to obtain
optimum conditions for natural healthful cooling will be performed.
For the cooling operation
FAN OPERATION
You can use the device simply as an air circulator. Use this function to dry the interior of the indoor
unit at the end of summer.
Press the FUNCTION selector so that the display indicates
(FAN).
Press the (FAN SPEED) button.*
Press the (START/STOP) button. Fan operation starts with
a beep. Press the button again to stop operation.
1
2
START
STOP
RESET
Содержание RAC-18GH5
Страница 26: ... 26 MEMO ...
Страница 36: ... C RESET C KÜHLBETRIEB J _ J J J J J J J J J J J J J J J J J J J J J 1 2 START STOP 3 ...
Страница 39: ... DEUTSCH J _ J J 2 3 _ J __ J J __ 4 5 J J J J J 3 J J J J J 2 _ J J __ 4 J J 3 J J J J J 2 ...
Страница 41: ... DEUTSCH Erläuterung der Einschlaf Zeitschaltuhr J J J J J J J J _ J _ J J _ _ J J J J NOTIZ ...
Страница 43: ... DEUTSCH AUSTAUSCHEN DER BATTERIEN DER FERNBEDIENUNG 1 2 VORSICHT J J ...
Страница 51: ... DEUTSCH MEMO J J J J J J J J _ _ J J J J J J _ J Anmerkung _ J J ...
Страница 52: ... MEMO ...
Страница 78: ... 78 MEMO ...
Страница 104: ... _ MEMO ...
Страница 130: ... 130 MEMO ...
Страница 156: ... 156 MEMO ...
Страница 182: ... 182 MEMO ...
Страница 208: ... 208 MEMO ...
Страница 209: ... 209 РУССКИЙ MEMO ...
Страница 210: ... 210 MEMO ...