 SAFETY PRECAUTION

Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit.

Pay special attention to signs of“ 

 Warning” and “ 

 Caution”. The “Warning” section contains matters which,if 

not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may result in 
serious consequences if not observed properly. Please observe all instructions strictly to ensure safety.
The signs indicate the following meanings.

   Make sure to connect earth line.

   The sign in the figure indicates prohibition.

   Indicates the instructions that must be followed.

Please keep this manual after reading.

PRECAUTIONS DURING INSTALLATION

WARNING

Do not reconstruct the unit.
Water leakage, fault, short circuit or fire may occur if you reconstruct the unit 
by yourself.

Please ask your sales agent or qualified technician for the installation of 
your unit. Water leakage, short circuit or fi re may occur if you install the unit 
by yourself.

Please use earth line. 
Do not place the earth line near water or gas pipes, lightning-conductor, or 
the earth line of telephone. Improper installation of earth line may cause 
electric shock.

CAUTION

A circuit breaker should be installed depending on the mounting site of the 
unit. Without a circuit breaker, the danger of electric shock exists.

Do not install near location where there is flammable gas. The outdoor unit 
may catch fire if flammable gas leaks around it.

Please ensure smooth flow of water when installing the drain hose.

PRECAUTIONS DURING SHIFTING OR MAINTENANCE



G

Should abnormal situation arises (like burning smell), please stop operating 
the unit and turn off the circuit breaker. Contact your agent. Fault, short 
circuit or fire may occur if you continue to operate the unit under abnormal 
situation.

Please contact your agent for maintenance. Improper self maintenance may 
cause electric shock and fire.

Please contact your agent if you need to remove and reinstall the unit. 
Electric shock or fire may occur if you remove and reinstall the unit yourself 
improperly.

If the supply cord is damaged, it must be replaced by the special cord 
obtainable at authorized service/parts centers.

PRECAUTIONS DURING OPERATION



G

Avoid an extended period of direct air fl ow for your health.

Do not put objects like thin rods into the panel of blower and suction side because 
the high-speed fan inside may cause danger.

Do not use any conductor as fuse wire, this could cause fatal accident.

During thunder storm, disconnect and turn off the circuit breaker.

Содержание RAC-10CZJ

Страница 1: ... UNIT SPLIT TYPE AIR CONDITIONER MODEL RAS 10CZJ RAC 10CZJ RAS 13CZJ RAC 13CZJ RAC 13CZJ Instruction manual Page 1 20 To obtain the best performance please read this instruction manual completely RAC 10CZJ OUTDOOR UNIT INDOOR UNIT RAS 10CZJ RAS 13CZJ ...

Страница 2: ...UTION A circuit breaker should be installed depending on the mounting site of the unit Without a circuit breaker the danger of electric shock exists Do not install near location where there is flammable gas The outdoor unit may catch fire if flammable gas leaks around it Please ensure smooth flow of water when installing the drain hose PRECAUTIONS DURING SHIFTING OR MAINTENANCE W A R N I N G Should ab...

Страница 3: ...door unit to avoid water dripping into the unit Dripping water will damage the insulator inside the unit and causes short circuit Do not place plants directly under the air flow as it is bad for the plants When operating the unit with the door and windows opened the room humidity is always above 80 and with the air deflector facing down or moving automatically for a long period of time water will co...

Страница 4: ...AL DEFLECTOR AIR OUTLET Refer page 12 REMOTE CONTROL Send out operation signal to the indoor unit so as to operate the whole unit Refer page 6 OUTDOOR UNIT DRAIN PIPE Condensed water drain to outside CONNECTING CORD AIR INLET BACK LEFT SIDE AIR OUTLET MODEL NAME AND DIMENSIONS MODEL WIDTH mm HEIGHT mm DEPTH mm RAS 10CZJ RAS 13CZJ 780 280 210 RAC 10CZJ 775 500 300 RAC 13CZJ 700 505 258 NAMES AND FU...

Страница 5: ...ioning use the Temporary Switch mode g n i t t e s s u o i v e r p e h t r e p s a e t a r e p o l l i w t i n u e h t d e s s e r p s i h c t i w S y r a r o p m e T e h t n e h W 1 2 P ress the Temporary Switch a second time will stop the operations of the air conditioner unit AUTO RESTART FUNCTION In the event of power failure the air conditioner will restart automatically In the event of power...

Страница 6: ...ress this button to stop operation only SLEEP button Use this button to set the sleep timer FAN SPEED selector This determines the fan speed Each time you press this button the intensity of circulation will change from AUTO to HI to MED to LOW during the AIR CIRCULATION mode from HI to MED to LOW AUTO SWING button Controls the angle of the horizontal air deflector and to turn off filter lamp TEMPERA...

Страница 7: ...5 28 C is recommended as the room temperature for cooling If the temperature setting is 27 C the room temperature will be controlled at around 27 C The temperature setting and the actual room temperature may vary somewhat depending on conditions COOLING OPERATION COOLING Cooling operation starts with a beep The cooling function does not start if the temperature setting is higher than the current r...

Страница 8: ...ntroller you only have to press the DEHUMIDIFY button to repeat the same settings next time Dehumidifying Function When the room temperature is higher than the temperature setting The device will dehumidify the room reducing the room temperature to the preset level When the room temperature is lower than the temperature setting Dehumidifying will be performed at the temperature setting slightly lo...

Страница 9: ...ATE Circulation Function Circulating operation starts with a beep Press the STOP button to stop operation As the settings are stored in memory in the remote controller you only have to press the CIRCULATION button to repeat the same settings next time When the setting temperature is higher than roomtemperature indoor fan will stop running During circulation operation compressor does not run and th...

Страница 10: ...the indoor unit Explanation of the sleep timer The device will control the FAN SPEED and room temperature automatically so as to be quiet and good for people s health You can set the sleep timer to turn off after 1 2 3 or 7 hours The FAN SPEED and room temperature will be controlled as shown below Operation with the sleep timer Function Operation Cooling and dehumidifying The room temperature will...

Страница 11: ...the button 1 2 3 9 1 0 1 1 1 2 1 hour interval Operation stop at setting time ON Timer Reservation ON TIME setting Select the ON TIMER by pressing the ON Button Setting time will change according to the below sequence 1 2 3 9 1 0 1 1 1 2 1 hour interval O p e ra t i o n w i l l s t a r t fo r s e t t i n g temperature at setting time The starting time may different depend on the room temperature a...

Страница 12: ...about 6 seconds may be required before the deflector starts to move Use the horizontal air deflector within the adjusting range shown on the right When the operation is stopped the horizontal air deflector moves and stops at the position where the air outlet closes CAUTION In Cooling operation do not keep the horizontal air deflector swinging for a long time Some dew may form on the horizontal air...

Страница 13: ...n the figure and take out the old batteries Install the new batteries The direction of the batteries should match the marks in the case CAUTION 1 Do not use new and old batteries or different kinds of batteries together 2 Take out the batteries when you do not use the remote controller for 2 or 3 months 3 Use high quality and high performance AAA batteries to avoid short operating life and electrol...

Страница 14: ...r operation mode together with your wake up time in the morning This will enable you to enjoy a comfortable room temperature Please use the timer effectively Do Not ForgetTo Clean Dusty Pre filter will reduce the air volume and the cooling efficiency To prevent from wasting electric energy please clean the filter every 2 weeks Temperatur e n Please Adjust SuitableTemperature For Baby And Children P...

Страница 15: ...e used for a long period of time please pull out the power plug Or the indoor unit still consumes about 3W in the operation control circuit even if it is in OFF mode OFF When Lightning Occurs Warning To protect the whole unit during lightning please stop operating the unit and remove the plug from the socket Interference From Electrical Products Caution To avoid noise interference please place the...

Страница 16: ...ted at the Pre filter If the accumulated dust is too much to be removed by vacuum cleaning apply mild detergent and flush the dust from the Pre filter with water After thorough rinsing leave the Pre filter lat a cool shaded place to dry 3 Re install the Pre filter to its original position With FRONT marker facing front Slightly lift up the opened front panel and close it by returning it to its orig...

Страница 17: ...ntwork of the front panel CAUTION Please disconnect the power plug before cleaning the front panel 1 2 3 Hot water 50 C Volatile liquid acid and others TROUBLE SHOOTING THE UNIT BEFORE CONTACTING SERVICE STAFF TO CHECK AND RECTIFY The air conditioner unit is not operating Check whether the power supply plug is properly plugged in Abnormal air conditioning effects Is the Pre filter clogged with dus...

Страница 18: ...abnormal for the operation 1 Slight flowing noise of refrigerant in the refrigerating cycle 2 Slight rubbing noise from the fan casing which is cooled and then gradually warmed as operation stops The odor will possibly be emitted from the room air conditioner because the various odor emitted by smoke foodstuffs cosmetics and so on sticks to it So please clean the air filter and the evaporator regula...

Страница 19: ...en the room light is dimmed a slight brightness fluctuation may occur This is of no consequence The conditions of the local Power Supply Companies are to be observed Note Avoid to use the room air conditioner for cooling operation when the outside temperature is below 21 C 70 F The recommended maximum and minimum operating temperatures of the hot and cold sides should be as below Minimum Maximum In...

Страница 20: ... 21 MEMO ...

Страница 21: ...Made in China Hitachi Household Appliances Wuhu Co Ltd ...

Отзывы: