background image

Preface .......................................................  1 
Safety Summary  ........................................  1 
How to Read This Manual ..........................  3 
Important Notice .........................................  4

System Configuration

 

1

 System Configuration

 .............................  5 

2

 Device Specification

 ...............................  6 

3

 Display....................................................  6

Calculating Air Conditioner Operation Ratio

1

 Calculation Result Reference .................  7 

2

 Displaying Data

 ...................................... 13 

3

 Sample Case .......................................... 20

4

 Setting Charge

 ....................................... 22

Maintenance and Service

1

 Data Backup Procedure ......................... 23

2

 How to Restore with Backup Data.......... 24

3

 Troubleshooting

 ...................................... 25

CONTENTS

Service

Before Usage

How to Use

HITACHI Air Conditioner 

Managing System

Central Station DX 

Management Software/

Operation Ratio

(PSC-AS2048WXB)

 

Thank you for choosing HITACHI Air 

 

Conditioner Managing System.
● Please keep this manual in a safe place.
● If you have any questions or concerns, 

please contact your local HITACHI dealer 
or HITACHI customer service. 

Operation Manual

Содержание PSC-AS2048WXB

Страница 1: ...22 Maintenance and Service 1 Data Backup Procedure 23 2 How to Restore with Backup Data 24 3 Troubleshooting 25 CONTENTS Service Before Usage How to Use HITACHI Air Conditioner Managing System Central Station DX Management Software Operation Ratio PSC AS2048WXB Thank you for choosing HITACHI Air Conditioner Managing System Please keep this manual in a safe place If you have any questions or concer...

Страница 2: ...fide gas form as hot spring drifts Places where flammable gas may be generated or exist Places where high in salt contents surrounding as coast regions Places where atmosphere of acidity and alkalinity humid place In case of using a medical equipment generating electro magnetic waves the system should be installed in an area where free from direct radiation to avoid malfunction The surface that is...

Страница 3: ...ck Please contact distributor or your dealer Do not disconnect the adapter from the computer while operation Data in the memory can be broken Other Important Notice Do not convert or change electric wiring It can cause serious electric shock or other unexpected accidents Keep the adapter away from water while cleaning This adapter is equipped with electrical parts which water can cause electric sh...

Страница 4: ...r Conditioner Operation Ratio In this chapter are described how to display operation ratio of each month and each data in detail Maintenance and Service In this chapter are described what are included in our service This manual consists of System Configuration Calculating Air Conditioner Operation Ratio and Maintenance and Service section ...

Страница 5: ...for operation ratio and calculation result are generated within 30 minutes after date changes If the software is shut down during this period data can not be saved which the adapter shall generate save data for the 2 days in a row on the following day Supported calculation method may vary on adapter types Refer to Setting Charge 4 Register Calc Mode of the installation manual P5414796 for detail T...

Страница 6: ...e package 1 System Configuration System Configuration Management Software PSC AS2048WXB CD ROM Computer for Management Not included in software package UPS Not included in software package Connect each air conditioner Hub for Ethernet Not included in software package H LINK Communication Wire Adapter PSC A128WX Connect each air conditioner LAN Ethernet Please carefully follow the instructions on I...

Страница 7: ...ort display by H H LINK only and tree view may not be selected Click the button to show display for registration and or confirmation window a Data Output Display Shows data in detail Switch to b Setting Charge Display Refer to 1 System Configuration for specification of the device in the system 2 Device Specification b Setting Charge Display Shows configuration data Switch to a Data Output Display...

Страница 8: ...day and hour respectively NOTE Ratio of electricity usage and Gas usage are calculated by either corresponding EHP or GHP The 4 files above will always be generated even if all the cycle adapts either EHP or GHP only Facility units only supports apportionment of electricity Operation ratio of facility units will be 0 when applied air conditioner operation ratio calculation 3 Reference Operation ra...

Страница 9: ...mal c Block No Block Name Block No 2 digits in decimal for No d Group No Group Name Group No First digit Alphabet Last two digits Decimal e Load on Indoor units In Mode I Thermo on time x capacity 8 digits In Mode II Accumulated expansion valve aperture x expansion valve coefficient 8 digits f Load on Outdoor units In Mode I Thermo ON time in the REFGN cycle x total capacity 8 digits In Mode II Ac...

Страница 10: ...door units c An day Elapsed days a Date YYYY MM DD 4 digits for year 2 digits each for month and day b Address H LINK number REFGN cycle address 2 digits In decimal c Block No Block Name Block No 2 digits in decimal for No d Group No Group Name Group No First digit Alphabet Last two digits Decimal e Load on Indoor units In Mode I Thermo on time x capacity 8 digits In Mode II Accumulated expansion ...

Страница 11: ...its for year 2 digits each for month and day b Accumulated load on outdoor units In Mode I Grand total of thermo on time x capacity of each indoor unit 12 digits In Mode II Accumulated electricity for operation for each outdoor unit 12 digits c An hour Elapsed time Current time Total elapsed time 7 digits 100 1000000 a Date b Accumulated load on outdoor units c An hour Elapsed time 0 00 1 00 2 00 ...

Страница 12: ...In decimal c Block No Block Name Block No 2 digits in decimal for No d Group No Group Name Group No First digit Alphabet Last two digits Decimal e Load on Indoor units In Mode I Thermo on time x capacity 8 digits In Mode II Accumulated expansion valve aperture x expansion valve coefficient 8 digits f Load on Outdoor units In Mode I Thermo ON time in the REFGN cycle x total capacity 8 digits In Mod...

Страница 13: ...on outdoor units c An hour Elapsed hour a Date YYYY MM DD 4 digits for year 2 digits each for month day and time respectively b Address H LINK number REFGN cycle address 2 digits c Block No Block Name Block No 2 digits d Group No Group Name Group No First digit Alphabet Last two digits Decimal e Load on Indoor units In Mode I Thermo on time x capacity 8 digits In Mode II Accumulated expansion valv...

Страница 14: ...isplay printing and CSV file will be changed Click to save as a csv file Click to show the detailed data of selecting group or unit Choose one from Hour Day and ALL for Time Period Units can be specified when H is selected Choose desired object to show the data Click to change hide show the dis played items Start Time specifies what time of data shall be the first entry Stop Time specifies before ...

Страница 15: ...d Gas meter H LINK No Cycle and Address to identify each unit and volt meter No and Gas meter No connected to the unit are shown in this column If other than Unit is selected in View by b will be shown in this column This item can not be hidden by Change button Volt meter No IU Volt meter No OU and Gas meter No will be described by a combination of H LINK Station Address INPUT No each lotted by hy...

Страница 16: ...ime This item shows elapsed operation time of the indoor unit g Thermo on time This item shows elapsed thermo on time of the indoor unit h REFGN flow amount This item shows accumulated REFGN flow amount of the indoor unit g f h ...

Страница 17: ...e 16 i j i Heater elapsed power distributing time This item shows elapsed power distributing time of the indoor unit j Accumulated running current This item shows accumulated running current of EHP outdoor unit ...

Страница 18: ...ng time This item shows elapsed power distributing time of EHP outdoor unit m Compressor heater on time This item shows elapsed compressor heater on time of GHP outdoor unit This item will not be shown if no GHP is connected The item can be shown by Change button ...

Страница 19: ...an be shown by Change button p Engine block heater on time This item shows elapsed engine block heater on time of GHP outdoor unit This item will not be shown if no GHP is connected The item can be shown by Change button q Accumulated outdoor load This item shows accumulated engine speed of GHP outdoor unit This item will not be shown if no GHP is connected p n q ...

Страница 20: ... the total amount data of all day will be shown NOTE Setting Uncharged Period is not available on this system t Uncharging If uncharged period is specified in Setting Charge Uncharged Period then the total amount data only in uncharged period will be shown If uncharged period is not specified in Setting Charge Uncharged Period then this item will not be shown The item itself can be shown by Change...

Страница 21: ...ycle 1 Address 2 30 1245 REFGN Cycle 1 Address 0 11 6829 REFGN Cycle 1 Address 1 16 9545 UNITS_20080102 csv Reference file of operation ratio by each air conditioner 2008 Jan 2 REFGN Cycle 0 Address 0 18 2498 REFGN Cycle 0 Address 1 22 4689 REFGN Cycle 1 Address 2 29 8531 REFGN Cycle 1 Address 0 9 7856 REFGN Cycle 1 Address 1 19 6426 Method Sample 1 Ratio of REFGN Cycle 0 Address 0 on 2008 Jan 1 i...

Страница 22: ...2008 01 01 03 2008 01 01 22 2008 01 01 23 38745 47565 26345 28742 2 Sample case for referencing file of operation ratio by an hour DAYS_200801 csv Operation ratio by each day 2008 Jan 2008 1 1 5 5687 2008 1 2 7 5478 2008 1 30 5 4862 2008 1 31 2 4789 HOURS_20080101 csv Operation ratio by an hour 2008 Jan 1 2008 Jan 1 0 00 3 8745 2008 Jan 1 1 00 4 7565 2008 Jan 1 22 00 2 6345 2008 Jan 1 23 00 2 8742...

Страница 23: ...Ratio on that day 5 5687 DAYS_200801 csv Ratio at 0 00 3 8754 HOURS_20080101 csv Ratio on REFGN Cycle 0 Unit 0 16 5484 UNITS_20080101_00 csv Then 0 05687 0 03745 0 165484 100 0 0352 2 Ratio on REFGN Cycle 0 Unit 0 at 1 00 2008 Jan 1 is Ratio on that day 5 5687 DAYS_200801 csv Ratio at 1 00 4 7565 HOURS_20080101 csv Ratio on REFGN Cycle 0 Unit 0 18 2498 UNITS_20080101_01 csv Then 0 055687 0 047565 ...

Страница 24: ...y 1 Connect USB flash drive or other external hard drive to management computer 2 Shut the management software 3 centralstation folder is saved under the drive in which the software is installed Copy the file to USB flash drive or other external hard drive connected to the computer 1 Data Backup Procedure 4 To remove the USB flash drive or other external hard drive select Safely remove hardware fr...

Страница 25: ...cedure please refer to Installation Operation Manual P5414794 2 Connect the USB flash device or other external hard drive with backup data saved in 1 to the new management computer 3 Overwrite the centralstation folder from the USB flash memory or other external hard drive in the drive in which the software is installed 4 Overwrite the newly created centralstation folder to the USB flash memory or...

Страница 26: ...is software outputs communication information for the period in which the adapter was off Is 1GB of free space assured in the management computer Clear the memory to assure more than 1GB of free space or substitute the computer with another with larger space Isn t the management computer set to standby state or hibernation state Management computer may not operate properly in standby or hibernatio...

Страница 27: ...e display to Operation ratio display pop up indicating Retry adapter exception schedule information acquisition is shown Did you change Schedule Settings This pop up is shown upon the entry to Operation ratio display after changing schedule settings 5 Upon switching the display to Operation ratio display pop up indicating Retry adapter connection information acquisition is shown Did you change Uni...

Страница 28: ...P5414797 P 2015 Printed in Japan SEG 2015 Johnson Controls Hitachi Air Conditioning Technology Hong Kong Ltd ...