Hd102
Sync.
Motor capacity
setting, 1st-motor
0.01
~
630.00
(kW)
Factory setting
Hd103
Sync.
Motor capacity
setting, 1st-motor
2
~
48(Pole)
4
Hd104
Sync.
Base frequency
setting, 1st-motor
10.00
~
590.00
(Hz)
60.00(JPN)(USA)/
50.00(EU)(ASIA)(CHN)
Hd105
Sync.
Maximum
frequency setting,
1st-motor
10.00
~
590.00
(Hz)
60.00(JPN)(USA)/
50.00(EU)(ASIA)(CHN)
Hd106
Sync.
Motor rated
voltage, 1st-motor
1
~
1000
(V)
(200V Class)
200(JPN)
230(EU)(USA)(ASIA)(CHN)
(400V Class)
400(JPN)(EU)(ASIA)(CHN)
460(USA)
Hd108
Sync.
Motor rated
current, 1st-motor
0.01
~
10000.00
(A)
Factory setting
Code/Name
Range (unit)
Initial
value
Pe
rm
an
en
t M
ag
ne
t
Sy
nc
hr
on
ou
s
M
ot
or
(S
M
/P
M
M
)
Hd110
Sync. Motor
Constant R, 1st-motor
0.000001
~
1000.000000 (Ω)
Factory
setting
Hd112
Sync. Motor
Constant Ld, 1st-motor
0.000001
~
1000.000000 (mH)
Factory
setting
Hd114
Sync. Motor
Constant Lq, 1st-motor
0.000001
~
1000.000000 (mH)
Factory
setting
Hd116
Sync. Motor
Constant Ke, 1st-motor
0.1
~
100000.0
(mVs/rad)
Factory
setting
Hd118
Sync. Motor
Constant J, 1st-motor
0.00001
~
10000.00000 (kgm2)
Factory
setting
・
Motor capacity and number of poles will be set by
Hitachi characteristics table
・
For SM/PMM, frequency, voltage, and the motor
characteristics are necessary.
・
If the maximum current is decided, sets with a margin
the overcurrent detection level [bb160].
Motor typical data
Code
Range of values (unit)
Capacity
[Hd102]
0.01
~
630.00 (kW)
Number of poles
[Hd103]
2
~
48 (Poles)
Frequency
[Hd104]
10.00
~
590.00 (Hz)
[Hd105]
10.00
~
590.00 (Hz)
Voltage
[Hd106]
1
~
1000 (V)
Current
[Hd108]
0.01
~
10000.00 (A)
※
Initial value depends on the inverter.
・
If motor capacity [Hd102], number of poles [Hd103] are
changed, the motor characteristics are set according to
the internal Hitachi table values.
・
By auto-tuning at stop, values of [Hd110]
~
[Hd114]
can be acquired.
[Hd130]
~
[Hd218]
Minimum frequency settings
Code/Name
Range (unit)
Initial
value
Hd130
Minimum Frequency for
Sync.M, 1st-motor
0
~
50(%)
8
Hd131
No-Load current for
Sync.M, 1st-motor
0
~
100(%)
10
・
By base frequency[Hd104]×[Hd130], change from Sync.
to sensorless is possible.
・
By [Hd131], the sensorless vector control no-load
current is set.
Magnetic pole position estimation SM(PMM)
Code/Name
Range (unit)
Initial
value
Hd132
Starting Method for
Sync.M, 1st-motor
00(Synchronous)/
01(Initial position
estimate)
00
Hd133
IMPE 0V wait number for
Sync.M, 1st-motor
0
~
255
3
Hd134
IMPE detect wait
number for Sync.M, 1st-motor
0
~
255
3
Hd135
IMPE detect number for
Sync.M, 1st-motor
0
~
255
10
Hd136
IMPE voltage gain for
Sync.M, 1st-motor
0
~
200(%)
100
Hd137
IMPE Mg-pole position
offset, 1st-motor
0
~
359(°)
15
・
By setting [Hd132] to initial position estimate, it will
estimate the pole position, for next runs will use the
saved position, unless it gets disconnected
・
Offset [Hd137] is added at the first start when doing
reverse motion.
IVMS setting
Code/
Range(unit)
Initial
Value
Hd-41
Carrier frequency at IVMS
0.5
~
16.0(kHz)
2.0
Hd-42
Filter gain of current
detection at IVMS
0
~
1000
100
Hd-43
VMS P-Gain for speed
control, SM(PMM)-IVMS
00,01,02,03
00
Hd-44
Open phase switching
threshold compensation
00(disable)/01(enable)
00
Hd-45
P gain for speed control
SM(PMM)-IVMS
0
~
1000
100
Hd-46
I gain for speed control
SM(PMM)-IVMS
0
~
10000
100
Hd-47
IVMS Wait time for open
phase switching
0
~
1000
100
Hd-48
Limitation of decision about
the drive direction, SM(PMM)-IVMS
00(disable)/01(enable)
00
Hd-49
open phase voltage detection
timing adjustment, SM(PMM)-IVMS
0
~
1000
10
Hd-50
Minimum pulse width
adjustment, SM(PMM)-IVMS
0
~
1000
100
Hd-51
IVM threshold current limit
0
~
255
100
Hd-52
IVMS threshold gain
0
~
255
100
・
Above parameters are for adjustment in SM(PMM) driving with
IVMS
Содержание P1-00041-H
Страница 6: ...0 5 Contents Contents Memo ...
Страница 42: ...2 26 Chapter 2 Installation and Wiring Memo ...
Страница 129: ...Index Index 3 memo ...
Страница 130: ...Index Index 4 memo ...