INSTALLING A FITTING
Before using the model NT50AGF Pneumatic Flooring Nailer, a 3/8”
Thread Fitting must be installed. The NT50AGF Pneumatic Flooring
Nailer has an adapter installed to accept a 3/8” Thread fitting. This
provides the owner the advantage of installing the preferred Fitting
of choice. (ie: Hitachi Fittings; Industrial (P/N 190051), Automotive
(P/N 190071)). This allows the freedom to use any configuration of
quick connect fitting with either a 3/8 NPT thread or a combination
of a 1/4 NPT thread fitting and 3/8 – 1/4 NPT reducer. Install the Fit-
ting into the supplied adapter and gently tighten.
CAUTION:
Do not remove the installed adapter. This adaptor pro-
vides connection of the Fitting of choice as well as protecting the
integrity of the NT50AGF Pneumatic Flooring Nailer Body from inlet
port damage.
IMPORTANT:
The
bottom hole of the
NT50AGF that is
plugged should
NEVER be removed.
If plug is removed,
the NT50AGF Pneu-
matic Flooring Nailer
will not perform cor-
rectly and serious
damage may occur.
CHANGING FLOORING SHOES
Loosen or remove Flange Nuts (Ref. No. 33) with Wrench and
unscrew the Shoe Screw (Ref. No. 50) to remove and change over
from Tongue Nailing to Face Nailing Applications. Change from
Face Nailing to Tongue Nailing by loosening or removing Flange
Nuts (Ref. No. 33) with Wrench and Face Shoe Screw (Ref. No. 42).
Always tighten the Shoe Screw (Ref. No. 50 or 42) before tightening
the Flange Nuts (Ref. No. 33).
33
50
33
42