36
CP-X2520 ( M2-25ED ) / CP-X3020 ( M2-30ED )
Wiring diagram 5
Wiring around PANEL DUCT
(1) Wire CNAIR, CNRC and AC-INLET cable
(2) Attach Wire #3000
Boss
AC-INLET
cable
Projection
Pay attention not to let
the cables protrude from
this rib to the lens side.
Fasten the #3000 and the
CNRC into the slit.
Pass the #3000
through his hook.
CNRC
CNGD1
PANEL DUCT
Put the excessive length of the
AC-INLET cable near the power
supply block.
Pass the CNGD1 between the PANEL
DUCT and the boss in order to keep
away from the POWER FAN.
Connect the CNAIR after attaching the PANEL
DUCT to the BOTTOM CASE in order to
prevent the components on the PWB
assembly SENSOR fro being damaged..
CNARI