29
3. ONE trigger mode
When trigger polarity setting is
POSITIVE
, after the trigger signal rise, exposure is start. At the trigger signal falling
edge, the internal VD signal is reset and the video data are transmitted. The trigger signal width equals the exposure
time.
One horizontal period and Period from exposure end to the following trigger input (*1) are different because of the
setting of the configuration and the clock frequency.
Cameralink output setting
One horizontal period
(*1)
Base configuration 40MHz
1H = 25.800
μ
s
More than (*2) + 3.25H
Base configuration 80MHz
1H = 12.900
μ
s
More than (*2) + 4.5H
Medium configuration 40MHz
1H = 12.900
μ
s
More than (*2) + 4.5H
Medium configuration 80MHz
1H = 6.450
μ
s
More than (*2) + 7H
Full configuration 40MHz
1H = 6.450
μ
s
More than (*2) + 7H
Full configuration 80MHz
1H = 3.225
μ
s
More than (*2) + 12H
(*2) is 1088H at partial scan OFF, and set value of width at partial scan ON.
Trigger input
(POS)
High
Low
Shutter time
Shutter time
(Integration time)
Data output
More than 10
μ
s
(*1)
FLASH OUT
FVAL
(*2)
Содержание KP-FM200WCL