16
2. Read command (Note: 1 to 7 and SUM need to be transformed into ASCII code)
1
2
3
4
5
6
7
Item
STX
STATUS ID NO.
AREA
ADDRESS
RELATIVE
NO.
DATA
ETX SUM
MODE
02
00
FF
81
04
00
00
00
03
21
POLARITY
02
00
FF
81
0F
00
00
00
03
10
SOURCE
02
00
FF
81
05
00
00
00
03
20
TRIGGER
BURST NUM
02
00
FF
81
07
00
00
00
03
1E
PRESET
02
00
FF
81
08
00
00
00
03
1D
VARIABLE VALUE
02
00
FF
81
11
00
00
00
03
23
MULTI SHUT NUM
02
00
FF
81
09
00
00
00
03
1C
SHUTTER
SPEED
INC EXP STEP
02
00
FF
81
0A
00
00
00
03
14
OUTPUT SIGNAL
02
00
FF
81
06
00
00
00
03
1F
CONFIG
02
00
FF
81
12
00
00
00
03
22
CLK
02
00
FF
81
19
00
00
00
03
1B
ACCEL
02
00
FF
81
13
00
00
00
03
21
DATA BIT
02
00
FF
81
14
00
00
00
03
20
GAIN
02
00
FF
81
0C
00
00
00
03
12
BLACK LEVEL
02
00
FF
81
17
00
00
00
03
1D
TEST PATTERN
02
00
FF
81
50
00
00
00
03
20
FLIP
02
00
FF
81
51
00
00
00
03
1F
AREA
02
00
FF
81
1E
00
00
00
03
0F
AREA1 START
02
00
FF
81
1F
00
00
00
03
0E
AREA1 WIDTH
02
00
FF
81
20
00
00
00
03
23
AREA2 START
02
00
FF
81
21
00
00
00
03
22
AREA2 WIDTH
02
00
FF
81
22
00
00
00
03
21
AREA3 START
02
00
FF
81
23
00
00
00
03
20
AREA3 WIDTH
02
00
FF
81
24
00
00
00
03
1F
AREA4 START
02
00
FF
81
25
00
00
00
03
1E
AREA4 WIDTH
02
00
FF
81
26
00
00
00
03
1D
AREA5 START
02
00
FF
81
27
00
00
00
03
1C
AREA5 WIDTH
02
00
FF
81
28
00
00
00
03
1B
AREA6 START
02
00
FF
81
29
00
00
00
03
1A
AREA6 WIDTH
02
00
FF
81
2A
00
00
00
03
12
AREA7 START
02
00
FF
81
2B
00
00
00
03
11
AREA7 WIDTH
02
00
FF
81
2C
00
00
00
03
10
AREA8 START
02
00
FF
81
2D
00
00
00
03
0F
PARTIAL
SCAN
AREA8 WIDTH
02
00
FF
81
2E
00
00
00
03
0E
The reading data from the Slave is based on "4. Comms command data format(2)" of "Remote control" (page 13).
Содержание KP-FM200WCL