Travelstar 5K160 (SATA) Hard Disk Drive Specification
142/167
14.40.2.11
Self-test completion time
These bytes are the minimum time in minutes to complete self-test.
14.40.2.12
Data Structure Checksum
The Data Structure Checksum is the 2’s compliment of the result of a simple 8-bit addition of the
first 511 bytes in the data structure.
14.40.3
Device Attribute Thresholds Data Structure
The following defines the 512 bytes that make up the Attribute Threshold information. This data
structure is accessed by the host in its entirety using the S.M.A.R.T. Read Attribute Thresholds. All
multi-byte fields shown in these data structures follow the ATA/ATAPI-6
specification for byte
ordering, namely that the least significant byte occupies the lowest numbered byte address location
in the field.
The sequence of active Attribute Thresholds will appear in the same order as their corresponding
Attribute Values.
Description Bytes
Offset
Format
Value
Data Structure Revision Number
2
00h
binary
0010h
1
st
Attribute Threshold
12
02h
(*1)
(*2)
...
..
...
..
30
th
Attribute Threshold
12
15Eh
(*1)
(*2)
Reserved 18
16Ah
(*3)
Vendor specific
131
17Ch
(*3)
Data structure checksum
1
1FFh
(*2)
512
(*1) - See following definitions
(*2) - Value varied by actual operating condition
(*3) - Filled with 00h
Figure 86 Device Attribute Thresholds Data Structure
14.40.3.1
Data Structure Revision Number
This value is the same as the value used in the Device Attributes Values Data Structure.
14.40.3.2
Individual Thresholds Data Structure
The following defines the 12 bytes that make up the information for each Threshold entry in the
Device Attribute Thresholds Data Structure. Attribute entries in the Individual Threshold Data
Structure is in the same order and correspond to the entries in the Individual Attribute Data
Structure.
Description Bytes
Offset
Format
Attribute ID Number (01h to FFh)
1
00h
binary
Attribute Threshold (for comparison with Attribute Values
from 00h to FFh)
1
01h binary
00h -
“
always passing
”
threshold value to be
used for code test purposes
01h -
minimum value for normal operation
FDh -
maximum value for normal operation