3.2.3 Interrupt Immediately after Reset
After a reset, if an interrupt were to be accepted before the stack pointer (SP: R7) was initialized,
PC and CCR would not be pushed onto the stack correctly, resulting in program runaway. To
prevent this, immediately after reset exception handling all interrupts are masked. For this reason,
the initial program instruction is always executed immediately after a reset. This instruction should
initialize the stack pointer (e.g. MOV.W #xx: 16, SP).
3.3 Interrupts
3.3.1 Overview
The interrupt sources include 13 external interrupts (IRQ
4
to IRQ
0
, WKP
7
to WKP
0
) and 23 internal
interrupts from on-chip peripheral modules. Table 3-2 shows the interrupt sources, their priorities,
and their vector addresses. When more than one interrupt is requested, the interrupt with the highest
priority is processed.
The interrupts have the following features:
•
Internal and external interrupts can be masked by the I bit in CCR. When the I bit is set to 1,
interrupt request flags can be set but the interrupts are not accepted.
•
IRQ
4
to IRQ
0
and WKP
7
to WKP
0
can be set to either rising edge sensing or falling edge
sensing.
65