293
Figure 10-17 Example of Multiprocessor Data Transmission Flowchart
Start
End
Read bit TDRE
in SSR
Sets bits SPC31 and
SPC32 to 1 in SPCR
1
3
2
Set bit MPDT
in SSR
Write transmit
data to TDR
Read bit TEND
in SSR
Clear bit TE to
0 in SCR3
Set PDR = 0,
PCR = 1
Yes
TDRE = 1?
No
Continue data
transmission?
No
TEND = 1?
Break output?
No
Yes
Yes
No
Yes
Read the serial status register (SSR)
and check that bit TDRE is set to 1,
then set bit MPBT in SSR to 0 or 1 and
write transmit data to the transmit data
register (TDR). When data is written to
TDR, bit TDRE is cleared to 0 automatically.
When continuing data transmission, be
sure to read TDRE = 1 to confirm that a
write can be performed before writing data
to TDR. When data is written to TDR, bit
TDRE is cleared to 0 automatically.
If a break is to be output when data
transmission ends, set the port PCR to 1
and clear the port PDR to 0, then clear bit
TE in SCR3 to 0.
1.
2.
3.