Offset
Beskrivelse
Værdier
Læs/Skriv
Availability
VRF
RAC-
ATW
147
Software LCD
Læs
O
148
Enhedens kapacitet
Læs
O
149
Unit Power Consumption
Læs
O
150
Water Outler HP (TwoHP)
0~100 kun YUTAKI S &
S Combi
Læs
O
151
Ta1av: Outdoor Unit Ambient Average
Temperature
-80~100
Læs
O
152
Ta2: Second Ambient Temperature
(inst)
-80~100
Læs
O
153
Ta2av: Second Ambient Temperature
(avg)
-80~100
O
154
O2: Water outlet Temp 2 (Two2)
-80~100
Læs
O
155
O3: Water outlet Temp 3 (Two3)
-80~100
Læs
O
156
Tg: Gas Temperature (THMg)
-80~100
Læs
O
157
Tl: Liquid Temperature (THMl)
-80~100
Læs
O
158
EVI: Indoor expansion valve openning
0~100
Læs
O
159
CD: Capacity Data
Læs
O
160
Mixing Valve Opening
0~100
Læs
O
161
Afrimning
0: No defrosting
Læs
O
1: Defrosting
162
Enhedsmodel
0: Yutaki S
Læs
O
1: Yutaki SC
2: Yutaki S80
3: Yutaki M
4: Yutaki SC Lite (New)
5: Yutampo (New)
6: YCC (New)
163
Th: Water Temp Setting (Ttwo)
-80~100
Læs
O
164
Vandgennemstrømning
Water Flow [0.1m3/h]
Læs
O
165
Pump Speed
0~100
Læs
O
166
Systemstatus 2
Bit 0: Defrost
Læs
O
Bit 1: Solar
Bit 2: Water Pump 1
Bit 3: Water Pump 2
Bit 4: Water Pump 3
Bit 5: Compressor ON
Bit 6: Boiler ON
Bit 7: DHW Heater
Bit 8: Space Heater
Bit 9: Smart function
input enabled
Bit10: Forced OFF
Bit11: DHW recirculation
Pump State
Bit12: Solar Pump
Output State
DRIFT
PMML0351A rev.4 - 04/2020