85
2.2.28 INC (increment
Operation
Rd + 1
→
Rd
Assembly-Language Format
INC Rd
Operand Size
Byte
Condition Code
I
H
N
Z
V
C
—
—
—
—
∆
∆
∆
—
I:
Previous value remains unchanged.
H:
Previous value remains unchanged.
N:
Set to 1 when the result is negative; otherwise cleared to 0.
Z:
Set to 1 when the result is zero; otherwise cleared to 0.
V:
Set to 1 when an overflow occurs (the previous value in Rd was H'7F); otherwise cleared
to 0.
C:
Previous value remains unchanged.
Description
This instruction increments an 8-bit general register and places the result in the general register.
Instruction Formats and Number of Execution States
Instruction code
Addressing
mode
Mnem.
Operands 1st byte 2nd byte
3rd byte 4th byte No. of states
Register direct
INC
Rd
0
A
0
rd
2