47
2.2.8 BCLR (bit clear)
Operation
0
→
(<Bit No.> of <EAd>)
Assembly-Language Format
BCLR #xx:3, <EAd>
BCLR Rn, <EAd>
Operand Size
Byte
Condition Code
I
H
N
Z
V
C
—
—
—
—
—
—
—
—
I: Previous value remains unchanged.
H: Previous value remains unchanged.
N: Previous value remains unchanged.
Z: Previous value remains unchanged.
V: Previous value remains unchanged.
C: Previous value remains unchanged.
Description
This instruction clears a specified bit in the destination operand to 0. The bit number can be
specified by 3-bit immediate data, or by the lower three bits of an 8-bit general register. The
destination operand can be located in a general register or memory.
The specified bit is not tested before being cleared. The condition code flags are not altered.