--- 13 ---
8-6. Insulation Tests
On completion of disassembly and repair, measure the insulation resistance, and conduct the dielectric strength
test.
Insulation resistance: 10 M
Ω
or more with DC 500 V megohm tester
Dielectric strength test: AC 4,400 V/3 minutes, with no abnormalities .................. 220 V --- 240 V products
AC 3,000 V/3 minutes, with no abnormalities .................. 110 V --- 127 V products
8-7. No-load Current Value
After no-load operation for 30 minutes, the no-load current value should be as follows.
Voltage (V)
Current (A) max.
110
3.4
120
3.2
230
2.1
240
2.0