When the “Clean Humidifying Filter” Indicator Comes On
Cleaning
Remove the water tank, and then
pull out the water tray.
Remove the humidifying filter from
the water tray.
Clean the humidifying filter, water tray and tray cover.
Install the water tray, and then
mount the water tank.
Plug the power cord in AC outlet
and press the reset button located
behind the panel.
Remove the panel.
Mount the panel on the unit.
Set the humidifying filter.
Slowly insert the humidifying filter into the tray cover.
Insert the filter fully until it comes into positive contact
with bottom of the tray. Inadequate fitting may cause
water leakage during operation.
Press the reset button located behind the panel.
(Use the tip of a ball-point pen or the like.)
Check that the “Clean” indicator is now OFF.
P.
E-19, E-20
P.E-8
When the purifier body is shaken or rocked, water may gather in other part of the water tray not to be
fitted with the humidifying filter.
After you pulled out the water tray, be sure to remove the tray cover and wipe off water or clean it.
Before cleaning, be sure to stop operation and unplug the power cord from AC outlet.
When the “Clean Humidifying Filter” indicator is lit, clean the humidifying filter, water tray and tray cover. The
“Clean Humidifying Filter” indicator will come on approx. one month (approx. 720 hours) after the start of use
or after the reset button was pressed upon finishing previous cleaning. Depending on the tap water used,
water scale may adhere earlier. If the filter contamination is heavy, clean the filter more than once a month
before the “Clean Humidifying Filter” indicator is lit.
When you are done with cleaning, press the reset button. The “Clean Humidifying Filter” indicator will go off.
Do not splash water on the purifier body. Water splash can be a cause of failure.
Do not use a volatile solvent, such as gasoline, thinner, benzene, wax, kerosene, alcohol, etc. or
polishing powder, or detergent (neither kitchen nor laundry use).
Such chemicals could cause deformation, discoloration, damage or removal of prints.
Do not tilt or tip over the unit.
When using a chemically treated cloth, follow its instructions.
Never use dryer or heater to dry the purifier case. Heating could cause deformation, discoloration,
damage or removal of prints.
Lay a soft cloth or the like beneath the purifier to protect the floor against scratch.
P.
E-9
When you pull out the water tray, water may spill out or the floor may be scratched with
bottom of the tray. Lay a soft cloth or the like beneath the purifier to protect the floor.
P.E-8
Water tray
Slowly pull out the
water tray while lifting
it obliquely upward.
Humidifying fi lter
Water tray
Humidifying fi lter
Reset button “Clean” indicator (Red)