English
— 12 —
4. About the thermal protection
The thermal protection operates to stop the motor when a
problem such as a motor overload, etc. occurs.
If the motor stops during operating, reset by pushing the
Reset switch (Refer to Fig. 6).
If the motor does not start or if it stops immediately,
proceed as follows.
(1) Place the knob of the pressure switch in the “OFF”
positon and disconnect the plug from the receptacle
(Fig. 2).
(2) Check for the following possible causes
fi
rst: lack
of proper ventilation, or an outside-air or room
temperature that is too high.
(3) If the extension cord does not conform to the
speci
fi
cations given on page 7 replace with an
extension cord such as that shown on page 7. If the
capacity of the power supply is insu
ffi
cient, increase
the power supply capacity to remove the cause of a
fl
ow of excessive current (over-current).
(4) Wait approximately 20 minutes.
(5) Start up. If the motor still stops during operation,
please contact the service center.
Protective breaker
Reset switch
Fig. 6
MAINTENANCE
WARNING
: Disconnect the compressor from
the power source and remove the
compressed air from the air tank
before performing the maintenance
operations. Allow the compressor
to cool before performing the
maintenance operations.
1. Draining
tank
Drain tank daily or after 4 hours of use. Open drain cock
and tilt compressor to empty accumulated water (Refer
to Fig. 5). Tank pressure should be below 10 psi when
draining the tank.
2. Cleaning the intake
fi
lter
Open the intake
fi
lter (Refer to Fig. 1) once a week and
clean the inside of the intake
fi
lter and the
fi
lter element
with compressed air (Fig. 7).
(1) Removal
Turn the intake
fi
lter counter-clockwise until it stops
and then remove the intake
fi
lter and
fi
lter element.
(2) Installation
After inserting the
fi
lter element, match the grooves of
the intake
fi
lter with the three protrusions on the main
unit so that the hose points downward. Then, turn the
intake
fi
lter clockwise until it stops. (Refer to Fig. 7)
Check to see if the intake
fi
lter is loose. If the
fi
lter is
loose, remove and reinstall the
fi
lter.
WARNING
: Never clean
fi
lter element with a
fl
ammable liquid or solvent.
CAUTION: Do not operate without the intake
fi
lter.
Intake
fi
lter
Filter element
Grooves (× 3)
Protrusions (× 3)
Fig. 7
NOTE:
Replace the
fi
lter element when it becomes dirty.
3. Maintenance
chart:
MAINTENANCE CHART
PROCEDURE
AFTER USE
DAILY
WEEKLY
Drain condensation in air tank
×
×
Inspect guards/covers
×
Check for unusual noise/vibration
×
Check for air leaks
×
Clean exterior of compressor
×
Check safety valve
×
Clean intake
fi
lter/
fi
lter element
×
SERVICE AND REPAIRS
All quality compressors will eventually require servicing or
replacement of parts because of wear and tear from normal
use. To assure that only genuine replacement parts will be
used, all service and repairs must be performed by a HITACHI
AUTHORIZED SERVICE CENTER, only.
NOTE:
Speci
fi
cations are subject to change without any
obligation on the part of the HITACHI.
000Book̲EC28M.indb 12
000Book̲EC28M.indb 12
2017/08/10 15:54:09
2017/08/10 15:54:09
Содержание EC 28M
Страница 35: ... 35 000Book EC28M indb 35 000Book EC28M indb 35 2017 08 10 15 54 10 2017 08 10 15 54 10 ...
Страница 36: ... 36 EC 28M 000Book EC28M indb 36 000Book EC28M indb 36 2017 08 10 15 54 10 2017 08 10 15 54 10 ...
Страница 38: ... 38 000Book EC28M indb 38 000Book EC28M indb 38 2017 08 10 15 54 11 2017 08 10 15 54 11 ...
Страница 39: ... 39 000Book EC28M indb 39 000Book EC28M indb 39 2017 08 10 15 54 11 2017 08 10 15 54 11 ...