NMI
The system supports NMI assertion, there are three possible NMI assertion sources, Chassis
Control command, PEF action, and Watchdog timer pre-interrupt. It is not available at
BIOS POST period.
Serial Over LAN
BMC supports 1 IPMI (Spec v2.0) specific SOL session. BMC supports redirect data from
UART interface.
DHCP
In addition to support static IP, the BMC support DHCP, DNS and dynamic update in DNS
(DDNS). When DHCP lease fails, BMC will use 192.168.0.120 as the default IP.
Time Sync
In BMC design, BMC does not have a local RTC to know what time it is. Each time BMC will
get the current time from system PCH after BMC boot. The current time is updated period-
ically from the PCH. The remote console program interpret this time as pre-initial.
SEL
BMC supports IPMI 1.5/2.0 standard SEL operation. It can keep SEL log. Event happened in
BIOS side will be logged by using Add SEL Entry command. BMC will store them in FLASH,
the time stamp field will be filled by BMC. When SEL is full, the new SEL won’t be logged
but will go through PEF as usual. If AC powers off, all SELs will remain in NV.
Platform Event
Platform Event Filter
The BMC implements selectable action on an event or LAN alerting base on event. By
default, no any PEF entries or actions exist, applications need to configure it to enable.
Dedicated and Shared NIC.
The number of Platform Event Filter Table is 40.
The number of Alert Policy Table and Alert Destination Table is 60.
The policy to match an event to Platform Event Filter Table entry is IPMI 1.5 standard.
The action support Power off, Power Reset, Power Cycle and NMI.
All Platform Event Filter Table is default disabled.
Содержание DS240
Страница 32: ...ABOUT THE SYSTEM MAINBOARD SLED 1 13 General SKU Air Duct Mainboard Repeater Module CPU Socket DIMM Slot ...
Страница 97: ...Rail Kit Assembly Chapter 3 ...
Страница 141: ...BMC Chapter 5 This section provides information and key features of BMC Baseboard Management Controller ...
Страница 168: ...CONNECTORS AND JUMPERS MAINBOARD 6 3 ...
Страница 169: ...Troubleshooting Chapter 7 This section provides guidance for troubleshooting errors and hardware failure notifications ...