11
White and black balance adjustment
Auto white balance error messages
When auto white balance adjustment fails, the following error messages will be displayed on the
screen for about 6 seconds.
Message
Cause
Correction
AUTO WHITE:NG
CHANGE TO CAM
TRY AGAIN
The color bar signal is output.
Press the D button to turn off the color bar
signal.
AUTO WHITE:NG
CHANGE WHITE BAL TO MEM
TRY AGAIN
White balance mode is set to
PRESET or AUTO.
Open the WHITE GAIN menu. Set the
W.BAL MODE to MEMORY.
AUTO WHITE:NG
LOW LIGHT
TRY AGAIN
Insufficient lighting for adjustment. Increase the lighting or set the MASTER
GAIN to up. In case the manual iris is
using at the lens, adjust the iris stop of the
lens. Then repeat white balance
adjustment.
AUTO WHITE:NG
LEVEL HIGH
TRY AGAIN
Excessive lighting for adjustment. Set the MASTER GAIN to down.
In case the manual iris is using at the
lens, adjust the iris stop of the lens.
Then repeat white balance adjustment.
AUTO WHITE:NG
C.TEMP.HIGH
CHANGE FILTER
TRY AGAIN
Color temperature adjustment is
too high.
Change ECC filter and readjust.
AUTO WHITE:NG
C.TEMP.LOW
CHANGE FILTER
TRY AGAIN
Color temperature adjustment is
too low.
Change ECC filter and readjust.
When the above error messages appear, correct the settings and repeat white balance adjustment.