background image

-8-

SERVICING AND REPAIRS

CAUTION: 

Be sure to disconnect the plug from the electrical outlet before

replacing the belt or the rotary brush.

*HOW TO REPLACE THE BELT 

(Fig. 21, 22)

The drive belt should be checked regularly to ensure that it is in good condition. If it is
stretched, cracked or cut, it should be replaced.
1. Turn the cleaner over. Release the handle to the middle position.

Remove the 3 screws from the belt cover. (Fig.21)

2. Remove the belt cover 

B

 as shown.

3. Lift the rotary brush assembly 

J

 out of the brush housing and remove the

worn or broken belt 

K

.

*HOW TO REPLACE THE ROTARY BRUSH 

(Fig. 23, 24)

Be sure to disconnect plug from the electrical outlet. Remove the belt cover, the
belt, and the rotary brush assembly following the direction previously given.
1. Grasp the rubber end caps and turn them counterclockwise until one of the end

caps comes off as shown in Fig.23.

2. Separate the rotary brush from other parts.
3. Reassemble each part with new rotary brush as shown in Fig.24. Be careful

not to forget to install any parts.

4. Screw on the end caps and tighten.
5. Replace the belt, the rotary brush and

the belt cover as described previously.

4. Place one end of the new belt over the motor shaft, and then slip the other end

around the pulley of the rotary brush. Reinstall the rotary brush back into
position.
Press firmly both sides of the rotary brush to be sure they are securely in place.

5. Place the four projections of the belt cover to the windows 

E

 provided on the

front end of the case and replace the belt cover, and re-fasten the screws
securely.

B

J

K

Fig.21

E

K

Fig.22

Fig.23

Fig.24

Trust washer

Rotary brush

End cap

Ball bearing

Bearing case

Shaft

Trust washer

Bearing case

Ball bearing

End cap

CV_90CY.p65

6/28/04, 3:23 PM

9

Содержание CV-90CY

Страница 1: ...How to use your HITACHI VACUUM CLEANER MODEL CV 90CY CV_90CY p65 6 28 04 3 23 PM 1 ...

Страница 2: ...iver straight type in the side hole of handle cover and detach it Fig 1 Curved joint pipe Dusting brush Cord storage hooks Flexible hose Carrying handle Hose storage hook cord storage hook Handle release pedal 3 positions Crevice nozzle Extension pipes Fig 2 Handle cover Side hole Handle Filter maintenance sign Clamp Dust compartment Front cover Furniture guard Duct hose ON OFF switch Handle cover...

Страница 3: ...ANDLE POSITION Fig 5 To change the position of the handle first press with foot on the handle release pedal at the rear of the cleaner and then lower the handle A Upright position When the handle is in this position the rotary brush is automatically raised away from the floor B Normal working position This position allows you to raise the front of the nozzle head to clear steps C Low position For ...

Страница 4: ... the cord and check whether the duct hose is clogged If so remove blockages NOTE If the cleaner is used when the orange sign appears in the window it will not draw enough air and the motor may overheat and may eventually burn out CARRYING HANDLE Fig 8 To move your cleaner from room to room carry it by the carrying handle 7 on the back of the cleaner or roll it on the rear wheels EDGE CLEANING Fig ...

Страница 5: ... them from the back of the cleaner The extension pipe assembly consists of two pipes with one located inside the other for storage 5 The tools can be connected as shown in Fig 12 NOTE After having finished using the tools re insert the tools and restore the flexible hose on body NOTE The extension pipes should be re inserted as shown in Fig 10 NOTE Rotary brush is not disconnected when tools are i...

Страница 6: ...uct hose by twisting counterclockwise and replace the hose supporter on the case securely 6 Place the four projections on the front of the belt cover to the windows E provided on the front end of case and replace the belt cover and re fasten the screws securely FLEXIBLE HOSE Fig 15 1 To disconnect flexible hose from the suction inlet press two joints F firmly 2 After removing blockage from the fle...

Страница 7: ...nt into a poly bag and press the open button to empty dust into the poly bag 5 Turn the dust compartment downwards push the open button for the lid of the dust compartment to release the dust 6 Remove dust around the mesh filter and under mesh filter Filter care Fig 18 It is recommended that the filter is cleaned once or twice a month to ensure optimum suction power 1 Empty the dust compartment as...

Страница 8: ...able Fig 19 After removing dust compartment pull the middle knob and remove Black filter Remove dust from the Black filter and install it to correct position HEPA clean filter Fig 20 1 Open the front cover while taking off the hook right side of the cover You can see HEPA clean filter and lower filter inside Remove the HEPA clean filter by pulling the handle on the filter 2 Remove dust around the ...

Страница 9: ...e rubber end caps and turn them counterclockwise until one of the end caps comes off as shown in Fig 23 2 Separate the rotary brush from other parts 3 Reassemble each part with new rotary brush as shown in Fig 24 Be careful not to forget to install any parts 4 Screw on the end caps and tighten 5 Replace the belt the rotary brush and the belt cover as described previously 4 Place one end of the new...

Страница 10: ...esult Avoid picking up sharp objects They may damage the vacuum cleaner and the bag Do not use the cleaner to pick up wet dirt and avoid using it in a wet and moist place as moisture may damage the motor and other mechanical parts Do not block the air flow Any blockages or obstructions to the nozzle hose etc or the exhaust air outlet can cause loss of power and motor overheating Do not run the cle...

Страница 11: ...ied out by a competent person preferably a qualified electrician If there is no alternative to cutting off the mains plug ensure that you dispose of it immediately having first removed the fuse to avoid a possible shock hazard by inadvertent connection to the mains supply IMPORTANT The wires in the mains lead are coloured in accordance with the following code Blue Neutral Brown Live As these colou...

Страница 12: ...erservice italy hitachi eu com HITACHI EUROPE S A S Lyon Office B P 45 69671 Bron Cedex FRANCE Tel 04 72 14 29 70 Fax 04 72 14 29 99 Email france consommateur hitachi eu com HITACHI EUROPE S A 364 Kifissias Ave 1 Delfon Str 152 33 Chalandri Athens GREECE Tel 1 6837200 Fax 1 6835694 Email service hellas hitachi eu com HITACHI EUROPE S A Gran Via Carles III 86 Planta 5a Edificios Trade Torre Este 08...