HOW TO MAINTAIN CLEANING EFFICIENCY

The plug of the power supply cord should be removed from the socket outlet
before cleaning the appliance or undertaking maintenance operations.

The supply cord on this appliance can only be replaced by the use of special
tools and if it is damaged the appliance must be returned to the manufacturer
or an accredited service agent for repair.

Empty the dust compartment before it is filled excessively.

If the rotary brush becomes jammed by picking up large solid objects, bulky
matter or the like, take it out after unpluging the cord. Remove any threads and
long strings entwined round the rotary brush after cutting through.

Only Hitachi special composition carbon brushes must be used in this cleaner.
Replacement of the brushes must be carried out by an Hitachi dealer/service
center.

To clean the cleaner body and attachments, wipe with a soapsuds-soaked
cloth. Avoid using alcoholic content liquids.

TO AVOID ACCIDENTS

Always disconnect cord from electrical outlet before servicing the cleaner.

Keep fingers, hands, feet and hair away from revolving rotary brush.

Do not pick up matches, fireplace ashes or smoking material with the
vacuum cleaner as a possible fire hazard may result.

Avoid picking up sharp objects. They may damage the vacuum cleaner
and the bag.

Do not use the cleaner to pick up wet dirt, and avoid using it in a wet and
moist place as moisture may damage the motor and other mechanical parts.

Do not block the air flow. Any blockages or obstructions to the nozzle,
hose, etc. or the exhaust air outlet can cause loss of power and motor
overheating.

Do not run the cleaner over cord. It may damage insulation.

Avoid cleaning the switch and receptacle parts with wet cloth and
splashing water on it as moisture may cause a short circuit.

Your vacuum cleaner is not a toy. Do not allow children to play with it. Do
not leave the vacuum cleaner connected to and electrical outlet unattended.

Warning: 

Electric shock could occur if used outdoors or on wet surfaces.

Warning:

 During use of the (accessory) tools, the rotary brush will continue to

rotate and care must be taken to keep hands and the mains lead clear of the
underside of the vacuum cleaner.

Warning: 

When using accessory tools, the rotary brush will continue to rotate,

so care must be taken not to leave the vacuum cleaner standing on an uneven
surface, e.g. stairs, as this may result in damage to a carpet or other surface.

Warning:

 Do not leave the vacuum cleaner running continuously on one part

of a floor surface, e.g. when answering the phone, as this may result in
damage. Switch off the vacuum cleaner.

CV_90CY.p65

6/28/04, 3:23 PM

10

Содержание CV-90CY

Страница 1: ...How to use your HITACHI VACUUM CLEANER MODEL CV 90CY CV_90CY p65 6 28 04 3 23 PM 1 ...

Страница 2: ...iver straight type in the side hole of handle cover and detach it Fig 1 Curved joint pipe Dusting brush Cord storage hooks Flexible hose Carrying handle Hose storage hook cord storage hook Handle release pedal 3 positions Crevice nozzle Extension pipes Fig 2 Handle cover Side hole Handle Filter maintenance sign Clamp Dust compartment Front cover Furniture guard Duct hose ON OFF switch Handle cover...

Страница 3: ...ANDLE POSITION Fig 5 To change the position of the handle first press with foot on the handle release pedal at the rear of the cleaner and then lower the handle A Upright position When the handle is in this position the rotary brush is automatically raised away from the floor B Normal working position This position allows you to raise the front of the nozzle head to clear steps C Low position For ...

Страница 4: ... the cord and check whether the duct hose is clogged If so remove blockages NOTE If the cleaner is used when the orange sign appears in the window it will not draw enough air and the motor may overheat and may eventually burn out CARRYING HANDLE Fig 8 To move your cleaner from room to room carry it by the carrying handle 7 on the back of the cleaner or roll it on the rear wheels EDGE CLEANING Fig ...

Страница 5: ... them from the back of the cleaner The extension pipe assembly consists of two pipes with one located inside the other for storage 5 The tools can be connected as shown in Fig 12 NOTE After having finished using the tools re insert the tools and restore the flexible hose on body NOTE The extension pipes should be re inserted as shown in Fig 10 NOTE Rotary brush is not disconnected when tools are i...

Страница 6: ...uct hose by twisting counterclockwise and replace the hose supporter on the case securely 6 Place the four projections on the front of the belt cover to the windows E provided on the front end of case and replace the belt cover and re fasten the screws securely FLEXIBLE HOSE Fig 15 1 To disconnect flexible hose from the suction inlet press two joints F firmly 2 After removing blockage from the fle...

Страница 7: ...nt into a poly bag and press the open button to empty dust into the poly bag 5 Turn the dust compartment downwards push the open button for the lid of the dust compartment to release the dust 6 Remove dust around the mesh filter and under mesh filter Filter care Fig 18 It is recommended that the filter is cleaned once or twice a month to ensure optimum suction power 1 Empty the dust compartment as...

Страница 8: ...able Fig 19 After removing dust compartment pull the middle knob and remove Black filter Remove dust from the Black filter and install it to correct position HEPA clean filter Fig 20 1 Open the front cover while taking off the hook right side of the cover You can see HEPA clean filter and lower filter inside Remove the HEPA clean filter by pulling the handle on the filter 2 Remove dust around the ...

Страница 9: ...e rubber end caps and turn them counterclockwise until one of the end caps comes off as shown in Fig 23 2 Separate the rotary brush from other parts 3 Reassemble each part with new rotary brush as shown in Fig 24 Be careful not to forget to install any parts 4 Screw on the end caps and tighten 5 Replace the belt the rotary brush and the belt cover as described previously 4 Place one end of the new...

Страница 10: ...esult Avoid picking up sharp objects They may damage the vacuum cleaner and the bag Do not use the cleaner to pick up wet dirt and avoid using it in a wet and moist place as moisture may damage the motor and other mechanical parts Do not block the air flow Any blockages or obstructions to the nozzle hose etc or the exhaust air outlet can cause loss of power and motor overheating Do not run the cle...

Страница 11: ...ied out by a competent person preferably a qualified electrician If there is no alternative to cutting off the mains plug ensure that you dispose of it immediately having first removed the fuse to avoid a possible shock hazard by inadvertent connection to the mains supply IMPORTANT The wires in the mains lead are coloured in accordance with the following code Blue Neutral Brown Live As these colou...

Страница 12: ...erservice italy hitachi eu com HITACHI EUROPE S A S Lyon Office B P 45 69671 Bron Cedex FRANCE Tel 04 72 14 29 70 Fax 04 72 14 29 99 Email france consommateur hitachi eu com HITACHI EUROPE S A 364 Kifissias Ave 1 Delfon Str 152 33 Chalandri Athens GREECE Tel 1 6837200 Fax 1 6835694 Email service hellas hitachi eu com HITACHI EUROPE S A Gran Via Carles III 86 Planta 5a Edificios Trade Torre Este 08...