88
8. Other Functions
Item
Description
Filter Status
1RWL¿FDWLRQ
The status to clean the air
fi
lter is changed.
• The timing of receiving Filter Error e-mail is depending on the FILTER
MESSAGE setting in the LAMP & FILTER item of the SETUP menu which
determines the period until the
fi
lter message is displayed on the projector
screen. An e-mail will be sent when the usage time of the
fi
lter exceeds the set
time limit. No noti
fi
cation e-mail will be sent if the FILTER MESSAGE is set to
TURN OFF. (
SETUP menu
in the
Operating Guide
)
•
Lamp Time Alarm
is a threshold for e-mail noti
fi
cation of the lamp time.
When the set time exceeds the limit con
fi
gured in the Projector Web Control,
an e-mail will be sent. Lamp Time Alarm can be enabled for both or either one
of lamp-1 and lamp-2.
•
Filter Time Alarm
is a threshold for e-mail noti
fi
cation of the
fi
lter time. When
the set time exceeds the limit con
fi
gured in the Projector Web Control, an e-mail
will be sent.
•
)LOWHU6WDWXV1RWL¿FDWLRQ
can be enabled for both or either one of
Status
1
and
2
. These noti
fi
cations are equivalent to the changing of the FILTER
indicator on the projector. (
Status 1
: off to orange,
Status 2
: orange to red)
Refer to the
Operating Guide
for details of the
FILTER
indicator.
• Lamp Error e-mail is sent as follows:
- When both lamps are in failure, “Lamp Error” is sent.
- When either one of lamps is in failure, “Lamp-1 Warning” or “Lamp-2 Warning”
is sent according to the failed lamp.
NOTE