19
3. Management with Web browser software
3.1 Con
guring and controlling the projector via a web browser (continued)
The Alert Items are shown below.
Item
Description
Alarm Time
Con
gures the time to alert.
(Only
Lamp Time Alarm
and
Filter Time Alarm
.)
SNMP Trap
Click
[Enable]
check box to enable SNMP Trap alerts.
Send Mail
Click
[Enable]
check box to enable e-mail alerts.
(Except
Cold Start
and
Authentication Failure
.)
Mail Subject
Con
gures the subject line of the e-mail to be sent.
The length of the subject line can be up to 100 alphanumeric
characters.
(Except
Cold Start
and
Authentication Failure
.)
Mail Text
Con
gures the text of the e-mail to be sent.
The length of the text can be up to 1024 alphanumeric
characters.
(Except
Cold Start
and
Authentication Failure
.)
Click
[Apply]
button to save the settings.
• The trigger of
Filter Error
e-mail is depending on the FILTER
MESSAGE setting in the SERVICE item of the OPTION Menu which de
nes
the period until the
lter message is displayed on the projector screen. The
e-mail will be sent when the
lter timer exceeds 500, 1000, 1500 or 2000 hours
based on the con
guration. No noti
cation e-mail will be sent if the FILTER
MESSAGE is set to TURN OFF. (
OPTION Menu in the User’s Manual
(detailed) – Operating Guide
)
•
Lamp Time Alarm
is de
ned as a threshold for e-mail noti
cation (reminder)
of the lamp timer. When the lamp hour exceeds this threshold that is con
gured
through the Web page, the e-mail will be sent out.
•
Filter Time Alarm
is de
ned as a threshold for e-mail noti
cation (reminder)
of the
lter timer. When the
lter hour exceeds this threshold, the e-mail will be
sent out.
NOTE