WIRING DIAGRAM 3
Wiring of the power supply block
Wiring of the power supply block
(1) Pass the CNPW1, CNPW2, TSW and CNFG2 through the wiring clamp of power supply case.
Do not make excessive length of the cables in power supply case. Make sure not to touch the primary.
(2) Attach the FEB1 to the CNPW1 and CNPW2.
(3) Attach the FEB1 to the upper surface of power supply case with cable tie.
(4) Bundle the CNPW1, CNPW2, TSW and CNFG2 with clamp.
(5) Attach the CNFG2 to the power supply case with screw.
(6) Pass the CNAC through the incision of insulation sheet.
Area of Importance
Area of Importance
about 90
degrees
Incision of
Insulation sheet
Wiring clamp
Clamp
Cross section
Power supply case
Attach the FEB1(ferrite core) to CNPW1 and CNPW2.
Make sure to completely lock the hook when attaching the FEB1.
Attach the FEB1 to the power supply case with cable tie.
Cut the excessive length of cable tie.
cable tie