-12-
Steel Ball D3.97
[62]
Spring (C)
[61]
Change Knob
[60]
Retaining Ring (E-Type) For
D5 Shaft
[44]
●
Reassembly of Change Knob
Reverse the disassembly procedures above to reassemble the jig saw. However, pay particular attention
when reassembling the jig saw.
1. Reassembly of Change Knob
(1) Reassemble Spring (C)
[61]
and Steel Ball D3.97
[62]
in Change Knob
[60]
as shown in the following
diagram:
2. Checking Insulator length
Do not strip too much insulation from the end of each lead wire for connection.
Be careful not to let the lead wire be clamped by the joint of Housing (A).(B) Set
[36]
.
3. Other precautions
(1) Make sure Earth Terminal
[54]
is completely inside Housing (A).(B) Set
[36]
before closing the set.
Otherwise, the set will be deformed.
(2) Be sure to reassemble Spring
[13]
and Plate Nut
[64]
, which are often overlooked and not mounted.
Reassembly