--- 18 ---
(9) Fix the Base Handle [77] by tightening the Base Bolt [84] as shown in Fig. 19.
(10) Tightening Torque of Screws and Bolts:
• M3 Special Screw [53]
0.8
0.2 N
•
m [8
2 kgf
•
cm, 0.6
0.1 ft-lb]
• D4 Tapping Screw [9][10][11][15][31][50]
1.96
0.49 N
•
m [20
5 kgf
•
cm, 1.4
0.4 ft-lbs]
• M4 x 16 Machine Screw [32]
2.45
0.49 N
•
m [25
5 kgf
•
cm, 1.8
0.4 ft-lbs]
• M4 x 10 Seal Lock Flat Hd. Screw [66]
1.96 --- 2.94 N
•
m [20 --- 30 kgf
•
cm, 1.4 --- 2.2 ft-lbs]
• M4 x 6 Hex. Socket Hd. Bolt [52]
2.94 --- 4.41 N
•
m [30 --- 45 kgf
•
cm, 2.2 --- 3.3 ft-lbs]
• M4 x 8 Hex. Socket Hd. Bolt [81]
4.41
0.3 N
•
m [45
3 kgff
•
cm, 3.3
0.2 ft-lbs]
• M5 x 10 Nylock Flat Hd. Screw [79]
1.96 --- 2.94 N
•
m [20 --- 30 kgf
•
cm, 1.4 --- 2.2 ft-lbs]
• M5 x 12 Hex. Socket Hd. Bolt [69]
3.92 --- 5.88 N
•
m [40 --- 60 kgf
•
cm, 2.9 --- 4.3 ft-lbs]
• Base Bolt [84]
7.84
0.49 N
•
m [80
5 kgf
•
cm, 5.8
0.4 ft-lbs]
10-3. Wiring Diagrams
For models without a noise suppressor, the wiring is in accordance with Fig. 20. For models with a noise
suppressor, the wiring is in accordance with Fig. 21.
Fig. 19
Cord
Switch
Controller circuit
Wiring block (C)
Armature
Stator
1
2
Fig. 20 Without noise suppressor
Base [82]
Base Bolt [84]
5
˚+ ---
2
˚
Base
Handle [77]
Mount the Base [82] to the main body positioning the handle at the back.