-10-
2. Checking after reassembly
(1) Check that the Lock Off Button
<4>
can be operated normally. Check that the trimmer does not operate
just by pulling the Trigger
<6>
.
(2) Push the Button
<34>
and check that Housing (R)
<43>
and Housing (L)
<41>
can be turned 180° and
locked correctly.
(3) Check the handle portion (Pipe Ass'y
<22>
) can be smoothly extended and retracted, and firmly
locked.
•
Tapping Screw ST3 x 6
[30]<32>
----------------------------------------------- 0.4 to 0.6 N
•
m (4 to 5 kgf
•
cm)
•
Tapping Screw ST4
[4][10]<1><11>
------------------------------------------- 1.1 to 1.3 N
•
m (11 to 13 kgf
•
cm)
•
M5 Nut
[44]<52>
-------------------------------------------------------------------- 2.0 to 3.0 N
•
m (20 to 30 kgf
•
cm)
Upon completing disassembly and repair, measure the insulation resistance and conduct an insulation test
(dielectric strength test).
Insulation resistance:
7 M
ȍ
or more
Dielectric strength:
4,000 VAC for 1 minute, with no abnormalities
After no-load operation for five minutes, the no-load current value at a frequency of 50 Hz should be as
follows:
Model CG 25SC: 2.2 A (max.)
Model CG 30SC: 2.3 A (max.)
Screw tightening torque
Insulation test
No-load current