38
CP-A100 / ED-A100 / ED-A110 (A1DN)
By the control panel
By the remote control transmitter
1. Display the Advanced menu by the
“MENU” button.(If EASY MENU
appears, choose “Go to Advanced
menu” to display ADVANCED
MENU.)
2. Select the “OPTION” on the menu.
3. Continue press the button [ ] fi rst,
then press the button [ ] together
with “INPUT”, and hold for 3
seconds.
1. Display the menu by the “MENU”
button. (If EASY MENU appears,
choose “Go to Advanced menu” to
display ADVANCED MENU.)
2. Select the “OPTION” on the menu.
3. Press the “MAGNIFY OFF” button.
Next hold the “MAGNIFY OFF”
button for 3 seconds.
To display the OSD for “HIDDEN SERVICE MENU” set up.
HIDDEN SERVICE
AIR-SENSOR EXECUTE
LAMP ALARM
NONE
STARTUP TYPE
1
PJLink
TURN OFF
PANEL TIME
1234h
LONG KEY
TURN OFF
NETWORK RESET
SOFT RESET
6-15 HIDDEN SERVICE MENU
6-16 RUN TIME window
AIR - SENSOR
Execute this item to adjust the air sensor.
LAMP ALARM
Select the lamp alarm level. 3 Level
ļ
1 Level
ļ
None
“3 Level” shows three kinds of lamp-messages according to the LAMP TIME count.
“1 Level” shows one kind of lamp-message according to the LAMP TIME count.
“None” shows no lamp-messages. It is the factory default setting.
STARTUP TYPE
Select the startup screen type. 1 : shows Hitachi Logo
2 : No Hitachi Logo
PJLink
Select the PJLink. Turn off
ļ
Turn on
PANEL TIME
Use time of LCD panel. Reset the PANEL TIME whenever you changed the LCD/LENS prism assembly.
LONG KEY
Projector react only to the key pressing the remote button for 3 seconds. Turn off
ļ
Turn on.
When LONG KEY mode is on, MY BUTTON1 behave as “LONG KEY DISABLE” and MY BUTTON2
behave as “LONG KEY ENABLE”.
NETWORK RESET
If this is executed, all of the network setting are initialized.
SOFT RESET
If this is executed, all of the user data is initialized. Never use it when not required.
Set operating time display method (accumulated lamp time display method)
1. Select “ OPTION” from the Advanced menu, then place the cursor on the “LAMP TIME”.
2. Press the [ ], [ENTER] or [RESET] button.
3. Press the [Reset] button once, then press [KEYSTONE] button of the remote control for 3 seconds or
more to display the screen shown below. (The menu will close after 10 seconds if there are no further
operations.)
4. Use [ ] or [ ] to select the usage status number. (The usage status is as shown below.)
Usage status number
0 ..... Total usage status
1 ..... Current usage status
2 ..... Usage status before first reset
3 ..... Usage status before second reset
||
9 ..... Usage status before eighth reset
RUN TIME
LAMP
Lamp time
1234 h
h
h
h
NORMAL
Lamp time(Normal)
1000
WHISPER
Lamp time(Whisper)
234
AC
2000
AC energizing time
On
Number of times on
1
Off
Number of times off
No.0
Usage status number(See below)
0
Содержание A1DN
Страница 14: ...14 CP A100 ED A100 ED A110 A1DN 5 Troubleshooting Check points ...
Страница 71: ...THIS PAGE INTENTIONALLY LEFT BLANK 71 ...
Страница 72: ...72 MEMO ...
Страница 92: ...92 CP A100 ED A100 ED A110 A1DN MEMO ...
Страница 93: ...CP A100 ED A100 ED A110 A1DN 1 2 3 4 5 6 1 2 3 4 5 6 A B C D E F G POWER UNIT BALLAST 1 ...
Страница 94: ...CP A100 ED A100 ED A110 A1DN 1 2 3 4 5 6 1 2 3 4 5 6 A B C D E F G POWER UNIT BALLAST 2 ...
Страница 95: ...CP A100 ED A100 ED A110 A1DN 1 2 3 4 5 6 1 2 3 4 5 6 A B C D E F G POWER UNIT CIRCUIT 1 ...
Страница 96: ...CP A100 ED A100 ED A110 A1DN 1 2 3 4 5 6 1 2 3 4 5 6 A B C D E F G POWER UNIT CIRCUIT 2 ...