
9. Refrigerant and water piping
TCGB0075 rev.0 - 11/2012
111
9
Piping size
(mm (inches))
Heating coil
DHW
From indoor unit
To indoor unit
From DHW insta-
llation
To DHW installa-
tion
DHWS-(195/260)S-2.0H1E
Ø19.05 (3/4”)
Ø19.05 (3/4”)
Ø19.05 (3/4”)
Ø19.05 (3/4”)
Heating coil and DHW pipes (factory supplied)
The DHW tank is factory supplied with two water pipes (heating coil pipes) to connect with the indoor unit (to the T-branch
and to the 3-way valve) and other two (DHW pipes) for connection with the DHW installation.
Factory-supplied
with the indoor unit
Heating coil pipes
Item
Connection
365mm
960mm
Ø19.05
(3/4”)
Heating coil inlet pipe
For the connection between the 3-way valve water out-
let and the heating coil inlet.
Heating coil outlet pipe
For the connection between the T-branch water inlet
and the heating coil outlet.
DHW pipes
Item
Connection
Ø19.05
(3/4”)
960mm
1045mm
DHW inlet pipe
For the connection between the DHW inlet con-
nection (cold water to the tank) and the DHW
installation.
DHW outlet pipe
For the connection between the DHW outlet con-
nection (hot water from the tank) and the DHW
installation.
N O T E
Please, refer to the
Installation and operation manual of the Domestic hot water tank of YUTAKI S80
for the detai-
led informatio
Содержание 7E300020
Страница 2: ......
Страница 4: ......
Страница 18: ......
Страница 54: ......
Страница 83: ...6 Working range TCGB0075 rev 0 11 2012 83 6 6 Working range Index 6 1 Working range 84 ...
Страница 94: ......
Страница 134: ......
Страница 146: ......
Страница 150: ......
Страница 156: ......
Страница 157: ......