8
English
Information concerning airborne noise and vibration
The measured values were determined according to Dr
prEN792-13.
The typical A-weighted single-event emission sound
pressure level: 97 dB.
The typical A-weighted single-event sound power level:
110 dB.
Wear ear protector.
The typical vibration characteristic value does not exceed
2.5 m/s
2
.
Shaft
Feeder
Sub Nail
Stopper
Main Nail Stopper
Fig. 22
(2) Open the nail guide and remove dust, etc., as shown
in
Fig. 21
. Apply lubricant to the sliding groove of the
feeder and feeder shaft. Check the main nail stopper
and sub nail stopper slide smoothly by pushing them
with your finger.
Fig. 21
(3) Also, apply the recommended oil to the feeding
surface of the tail cover and nail guide after cleaning.
This promotes smooth operation and retards
corrosion.
CAUTION:
䡬
Check for smooth movement of the feeders and
stoppers before use. If movement is uneven, nails
could be fired at an irregular angle, presenting a
hazard to the operator and others nearby.
COMPRESSOR
CAUTION:
䡬
When the maximum, operating pressure of the air
compressor exceeds 8.3 bar (120 psi.), be sure to
provide a reducing valve between the air compressor
and nailer. Then, adjust the air pressure within the
operating range of 4.9 ~ 8.3 bar (70 ~ 120 psi.). If the
air set is installed, lubrication is also possible, thus
providing additional convenience.
OILER-FILTER-REDUCING VALVE (Air Set)
So that the equipment can be operated under an optimum
condition to ensure extended service life, it is advisable
to use an oiler filter reducing valve. Please limit the
length of the hose between the unit and the air set to
within 10m when using.
APPLICABLE LUBRICANTS
Type of lubricant
Name of lubricant
Recommended oil
SHELL TONNA
Motor oil
SAE10W, SAE20W
Turbine oil
ISO VG32 ~ 68
(#90 ~ #180)
Filter
Oiler
Reducing Valve
➡
Compressor
Side
➡
Nailer
Side