GENERAL INFORMATION
- 50 -
Self-powered test light
A self-powered test light can be constructed from a 12-volt light bulb, a pair of test leads and a
12-volt battery. When the test leads are touched together, the light bulb should go on.
Use a self-powered test light as follows:
1. Touch the test leads together to make sure the light bulb goes on. If not, correct the problem before
using it in a test procedure.
2. Select two points within the circuit where there should be continuity.
3. Attach one lead of the self-powered test light to each point.
4. If there is continuity, the self-powered test light bulb will come on.
5. If there is on continuity, the self-powered test light bulb will not come on, indicating an open circuit.
Ohmmeter
An ohmmeter measures the resistance (in ohms) to current flow in a circuit or component. Like the
self-powered test light, an ohmmeter contains its own power source and should not be connected to a
live circuit.
Ohmmeter may be analog type (needle scale) or digital type (LCD or LED readout). Both types of
ohmmeter have a switch that allows the user to select different ranges of resistance for accurate
readings. The analog ohmmeter also has a set-adjust control which is used to zero or calibrate the
meter (digital ohmmeters do not require calibration).
An ohmmeter is used by connecting its test leads to the terminals or leads of the circuit or
component to be tested. If an analog meter id used, is must be calibrated by touching the teat leads
together and turning the set-adjust knob until the meter needle reads zero. When the leads are
uncrossed, the needle reads zero. When the leads are uncrossed, the needle should move to the
other end of the scale indicating infinite resistance.
During a continuity test, a reading of infinity indicates that there is an open in the circuit or
component. A reading of zero indicates continuity, that is, there is no measurable resistance in the
meter needle falls between these two ends of the scale, this indicates the actual resistance, multiply
the meter reading by the ohmmeter scale. For example, a meter reading of 5 multiplied by the R×100
scale is 5000 ohms of resistance.
CAUTION
Never connect an ohmmeter to a circuit
which has power applied to it. Always
disconnect the battery negative lead before
using an ohmmeter.
Jumper wire
A jumper wire is a simple way to bypass a potential problem and isolate it to a particular point in a
circuit. If a faulty circuit works properly with a jumper wire installed, an open exists between the two
jumper points in the circuit.
To troubleshoot with a jumper wire, fist use the wire to determine if the problem is on the ground
side or the load side of a device. Test the ground by connecting a jumper between the lamp and a
good ground. If the lamp does not come on with the jumper installed. The lamp’s connection to ground
Содержание HS800UTV 2014
Страница 91: ...SPECIFICATIONS 79 HYDROGRAPHIC CHART Hydrographic chart Pressure ...
Страница 92: ...SPECIFICATIONS 80 LUBRICATION OIL WAY LUBRICATION OIL WAY Pressure splashing oil ...
Страница 165: ...ENGINE 153 No Part Name Qty Remarks 12 Oil pressure sensor 1 For installation reverse the removal procedure ...
Страница 208: ...CHASSIS 196 No Part Name Qty Remarks 11 Pad spring 2 12 Brake pad holding bolt 4 13 Hexagon flange bolt M10 1 25 22 8 ...
Страница 216: ...CHASSIS 204 No Part Name Qty Remarks 11 Pad spring 2 12 Brake pad holding bolt 4 13 Hexagon flange bolt M10 1 25 22 8 ...
Страница 278: ...CHASSIS 266 No Part Name Qty Remarks 19 Impeller 1 20 Cover water pump 1 21 Clip 1 22 Water pipe 1 ...
Страница 289: ...CHASSIS 277 Fuel tank cap Remove the fuel tank cap by turning it counterclockwise ...
Страница 353: ......
Страница 354: ......
Страница 355: ......
Страница 356: ......
Страница 357: ......
Страница 358: ......
Страница 359: ......
Страница 360: ......
Страница 361: ......