![Hisun Motors HS5D-EV Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/hisun-motors/hs5d-ev/hs5d-ev_manual_2139336038.webp)
38
5201
Heatsink overtemp
Controller heat sink has
reached critical high
temperature, and has shut
down.
52C1
Encoder Fault
Encoder input wire-off is
detected.
52C2
Motor Overcurrent Fault
Motor current exceeded
controller rated maximum
52C3
Current Control Fault
Motor controller unable to
maintain control of motor
currents
52C4
Motor Overspeed Fault
Motor control tripped due to
motor overspeed
52C5
Encoder Alignment Severe
Encoder is not aligned properly.
52C6
di/dt fault (suspected s/c)
Large rate of change of current
detected multiple times.
Suspected MOSFET, motor or
wiring short circuit.
52C7
Vcap Overvotlage (software
overvoltage)
Measured capacitor voltage has
exceeded controller maximum.
5301
CANBUS Fault
CANbus fault condition
detected on multinode system.
5302
Bootup not received
CANopen slave has not
transmitted boot up message at
power up
5303
LPRX queue overrun
CANbus fault condition
detected on multinode system.
5304
LPTX queue overrun
CANbus fault condition
detected on multinode system.
5305
HPRX queue overrun
CANbus fault condition
detected on multinode system.
5306
HPTX queue overrun
CANbus fault condition
detected on multinode system.
5307
CAN overrun
CANbus fault condition
detected on multinode system.
5308
CAN off bus
CANbus fault condition
detected on multinode system.
5309
Nodeguarding Failed
Not used
530A
Short PDO received
Received RPDO doesn't
contains enough bytes
530B
CANopen Heartbeat Failed
Heartbeat not received within
configured time out (0x1016)
530C
CANopen slave in wrong state
CANopen slave has changed to
unexpected state
530D
CAN ESTAT set
Internal CANbus fault
530E
SDO HDL Error
Internal CANbus fault
530F
SDO Timeout Error
Internal CANbus fault
5310
SDO Abort Error
Internal CANbus fault
5311
SDO State Error
Internal CANbus fault
5312
SDO Toggle Error
Internal CANbus fault
5313
SDO Rec Error
Internal CANbus fault
5314
SDO Len Error
Internal CANbus fault
5315
SDO Send Error
Internal CANbus fault
5316
SDO unknown event
Internal CANbus fault
5317
SDO Bad SRC
Internal CANbus fault
5318
SDO bad error number
Internal CANbus fault
Содержание HS5D-EV
Страница 4: ...4 Cleaning and Storage 71 Storing the Vehicle 74 Specifications Table 75...
Страница 10: ......
Страница 12: ......
Страница 15: ...15 5 6 7 8...
Страница 23: ......
Страница 24: ......
Страница 40: ...40 non Sevcon node and anonymous EMCY level 0x2830 0 is set to 5...
Страница 46: ......