33
(0x2790,1) is less than BDI
Cutout level (0x2C30,4)
45C3
Low Battery Cut
Battery voltage (0x5100,1) is
less than Under Voltage limit
(0x2C02,2) for longer than the
protection delay (0x2C03,0)
45C4
High Battery Cut
Battery voltage (0x5100,1) is
greater than Over Voltage limit
(0x2C01,2) for longer than the
protection delay (0x2C03,0)
45C5
High Capacitor Cut
Capacitor voltage (0x5100,3) is
greater than Over Voltage limit
(0x2C01,2) for longer than the
protection delay (0x2C03,0)
45C6
Vbat below rated min
Battery voltage (0x5100,1) is
less than rated minimum
voltage for controller for longer
than 1s.
NOTE: This fault is sometimes
seen at power down.
45C7
Vbat above rated max
Battery voltage (0x5100,1) is
greater than rated maximum
voltage for controller for longer
than 1s.
45C8
Vcap above rated max
Capacitor voltage (0x5100,3) is
greater than rated maximum
voltage for controller for longer
than 1s.
45C9
Motor in low voltage cutback
Motor control (DC link) has
entered low voltage cutback
region.
45CA
Motor in high voltage cutback
Motor control (DC link) has
entered high voltage cutback
region.
45CD
KL15/30 Too Low
The voltage applied to the
KL15/30 is below the controller
rated minimum
4601
Device too cold
Low heatsink temperature
(0x5100,4) has reduced power
to motor
4602
Device too hot
High heatsink temperature
(0x5100,4) has reduced power
to motor
0x4603
Motor in thermal cutback
High measured (0x4600,3) or
estimated (0x4602,8) motor
temperature has reduced power
to motor
4604
Motor too cold
Low Measured temperature has
reached -30deg
4681
Unit in preoperational
Controller is in pre-operational
state
4682
IO can't init
Controller has not received all
configured RPDOs at power up
4683
RPDO Timeout (warning)
One or more configured RPDOs
not received with 3s at start up
or 500ms during normal
Содержание HS5D-EV
Страница 4: ...4 Cleaning and Storage 71 Storing the Vehicle 74 Specifications Table 75...
Страница 10: ......
Страница 12: ......
Страница 15: ...15 5 6 7 8...
Страница 23: ......
Страница 24: ......
Страница 40: ...40 non Sevcon node and anonymous EMCY level 0x2830 0 is set to 5...