- 11 -
4-3 SERVICE DIAGNOSIS CHART
Problem
Possible Cause
Appliance does not operate.
Not plugged in.
The appliance is turned off.
The circuit breaker tripped or a blown fuse.
Appliance is not cold enough.
Check the temperature control setting. External
environment may require a higher
setting.
The door is opened too often.
The door is not closed completely.
The door gasket does not seal properly.
NO cooling enough
The room temperature is hotter than normal.
A large amount of contents has been added to the wine chiller.
The door is opened too often.
The door is not closed completely.
The temperature control is not set correctly. The door
gasket does not seal properly.
The light does not work.
Not plugged in.
The circuit breaker tripped or a blown fuse. The bulb has
burned out.
The light button is
“OFF”.
Energy conservation button is on.
button is on.
Vibrations.
Check to assure that the Wine Chiller is level.
The Wine Chiller seems to make too much noise.
The rattling noise may come from the flow of the refrigerant,
which is normal.
As each cycle ends, you may hear gurgling
sounds caused by the flow of refrigerant in your
Wine Chiller.
Contraction and expansion of the inside walls may cause
popping and crackling noises.
The Wine Chiller is not level.
The door will not close properly.
The Wine Chiller is not level.
The door was reversed and not properly installed. The gasket is
dirty.
The shelves are out of position.
Display error code
“
E3
” or “
E4
”.
(
Models
:
RW54N1SSD
):The defrost sensor is failed.
Display error code
“
E7
” or “
E8
”.
(
Models
:
RW46N1DSD
):The lower zone sensor is failed.
Display error code
“
E0
” or “
E1
”.
(
Models
:
RW54N1SSD
):The inner sensor is failed.
(
Models
:
RW46N1DSD
):The upper zone sensor is failed.