4
2
3
1
4
2
3
1
4
2
3
1
3
ON
5 6
4
1 2
1
ON
3 4
2
1
ON
2
1
ON
2
1
ON
2
1
ON
2
1
ON
2
1
ON
2
3
ON
5 6
4
1 2
1
ON
3 4
2
1
ON
2
1
ON
2
1
ON
2
1
ON
2
1
ON
2
1
ON
2
PCN2
PCN1
LED2
LED1
LED4 LED5 LED6 LED7
LED3
DSW3
DSW2
DSW1
TP
CN11
DSW8
DSW7
DSW6
DSW5
DSW4
CN9 CN10
CN8
CN7
CN6
CN5
CN4
CN12
LED17
LED16
LED15
LED14
LED13
LED12
LED11
LED10
CN1
CN2
CN3
PCN2
PCN1
LED2
LED1
LED4 LED5 LED6 LED7
LED3
DSW3
DSW2
DSW1
TP
CN11
DSW8
DSW7
DSW6
DSW5
DSW4
CN9 CN10
CN8
CN7
CN6
CN5
CN4
CN12
LED17
LED16
LED15
LED14
LED13
LED12
LED11
LED10
CN1
CN2
CN3
3
ON
5 6
4
1 2
1
ON
3 4
2
1
ON
2
1
ON
2
1
ON
2
1
ON
2
1
ON
2
1
ON
2
PCN2
PCN1
LED2
LED1
LED4 LED5 LED6 LED7
LED3
DSW3
DSW2
DSW1
TP
CN11
DSW8
DSW7
DSW6
DSW5
DSW4
CN9 CN10
CN8
CN7
CN6
CN5
CN4
CN12
LED17
LED16
LED15
LED14
LED13
LED12
LED11
LED10
CN1
CN2
CN3
UTILISER DES FILS
D' ALIMENTATION EN CUIVRE.
ATTENTION
USE COPPER SUPPLY WIRES.
CAUTION
17E26034A
Control Wiring Connection
(3 x
φ
26mm [1 inch])
Power Supply Wiring Connection
for Conduit Tube (
φ
22.2mm [7/8 inch])
Cable Clamp
Cable Clamp
Clamp
(Accessory (7))
Communication Cable
Communication cable between the
outdoor unit and Switch Box.
Cable Clamp
Clamp
(Accessory (7))
Cable Clamp
Clamp
(Accessory (7))
Terminal Block
for Power Supply
Ground Terminal
Terminal Blocks for Communication
between Switch Box and Indoor Unit
Wire Clip
(Use to
route wiring)
D
C
B
A
H
G
F
E
L
K
J
I
TB1
PCB3
PCB2
PCB1
TB2
TB3 TB4
TB3 TB4
TB3 TB4
TB1:
Terminal
Block
for
Power
Supply
TB2:
Terminal
Block
for
Communication
TB3,
TB4:
Terminal
Block
for
Communication
Figure
6.1
Electrical
Wiring
Connection
6.3 Electrical Wiring
The electrical wiring connection for the
Switch Box
is shown in Figure 6.1.
(1)
Turn OFF the main power switch and take off the electrical box cover of
Switch Box.
(2)
Connect the power supply wiring to L1 and L2 on the terminal block TB1, and connect ground wiring to
the
terminals in the electrical box.
(3)
Connect the communication cable between the outdoor unit and
Switch Box
to TB2 of the
Switch Box.
(4)
Tightly clamp the wires using the cable clamp inside the electrical box.
(5)
Make sure the communication cables outside the electrical box does not touch sharp edges by
securing with
clamp (accessory (7)).
(6)
Attach the electrical box cover after completing the wiring work.
NOTE:
The
accessory
numbers
are
listed
in
Table
4.1.
Above figure illustrate the example of
HCHM-N12X.
Number of PCBs are different depending on model
number.
Refer to the following table.
PCB1
PCB2
PCB3
PCB4
HCHM-N04X
HCHM-N08X
HCHM-N12X
HCHM-N16X
Connect
the communication cable between the
Switch Box
and indoor unit to TB3 and TB4 of
the Switch Box.
Ensure that the communication cable between the
Switch Box
and indoor unit
is connected to the
same
letter as piping connection .<Tightening Torque: 1.0 to 1.3 N.m (0.7 to 1.0 ft-lbs)
>
Refer to "Example or Electrical Wiring" for the wring connection.