Hisense 49SOA25PT Скачать руководство пользователя страница 17

Hisense B2B 

 

 

 

9

 

Power on testing

 

9.1

 

safety testing

 

Safety testing already done before shipping. If customers want to change wiring and other parts (like change 
power cable, increase other electrical parts, etc.), please make safety testing before power-on to check any 
short circuit. This operation shall be implemented under the guidance of professional electrical engineer with 
multi-meter. 

 

 

9.2

 

Power-on procedure

 

9.2.1

 

External power supply

 

Make sure voltage of power supply is compatible with the product before power on. 

9.2.2

 

Switch off power

 

After switch off, the display is inactive state, the default state is switch on, please shut down and switch off 
before maintenance 

 

 

 

9.2.3

 

Display status test

 

The screen is in blue or playing content in normal condition and the internal fan start running. 

Содержание 49SOA25PT

Страница 1: ...Beyond An Immersive Experience 2022 User Manual Outdoor Series 49OA25PT Issue Date 14 04 2022 Copyright 2022 All Rights Reserved...

Страница 2: ...on 3 2 2 Power Voltage 4 2 3 Avoid Water 4 2 4 No Touch 4 2 5 Avoid Open Flame 4 2 6 Installation Place 4 2 7 Cooling Performance 4 2 8 Clean or Maintenance 4 2 9 Cleaning 4 2 10 Expert Engineer Requi...

Страница 3: ...13 8 3 Installation Hole 14 8 4 Lift product 14 9 Power on testing 16 9 1 safety testing 16 9 2 Power on procedure 16 9 2 1 External power supply 16 9 2 2 Switch off power 16 9 2 3 Display status tes...

Страница 4: ...etc 1 2 Content This manual is introduction for 49SOA25PT include structure technical parameters installation usage maintenance as well as troubleshooting 1 3 Operation instructions Please make sure...

Страница 5: ...Flame Do not install it nearby open flame area and no fire closed to the display 2 6 Installation Place Please follow the instructions and install it firmly on the ground or bracket to prevent any LC...

Страница 6: ...sonal injury 3 Power cable The power cable is 3 meters if no particular request The cable is placed in the bottom of cabinet under display Customer can use or change different cable length as per need...

Страница 7: ...Hisense B2B 6 4 Overall size mm Power Cable...

Страница 8: ...tion 1080 1920 Brightness 2500cd m2 Viewing angle 178 Contrast ratio 3000 1 IP rating IP65 Cooling system Air conditioner Working temp 40 50 Working Humidity 5 100 Working Voltage 220V 10 50HZ Consump...

Страница 9: ...Hisense B2B 8 Rear door Speaker Installation hold Eyebolt LCD 6 2 2D View Door for A C 6 3 Door opening Step 1 Step 2 Step 3 Air ventilation for A C...

Страница 10: ...ure inside Fan Android board Power LCD Switch Reserved Space Power Socket A C 6 5 Cable entrance hole 3 cable entrance hole for A C power cable external power cable and LAN cable Cable entrance hole f...

Страница 11: ...isense B2B 1 7 A C Installation 7 1 A C Removal 7 1 1 Open the A C door A C 7 1 2 Disconnect power cable to A C 7 1 3 Take out A C Draw out tray and take out A C Unscrew and remove Turn the rocker dow...

Страница 12: ...Hisense B2B 1 7 1 4 Draw out tray and take out A C Tray 7 2 A C installation 7 2 1 Put A C in the tray and fix it by rocker Rocker 7 2 2 Connect power cable to A C as below...

Страница 13: ...o less than 800mm to the rear of the cabinet 8 Installation 8 1 Caution before installation 8 1 1 Installation Place Environment This is floor standing mount ensure the concrete must be solid and we p...

Страница 14: ...low to custom concrete foundation the overall size should be larger than base plate size recommended depth of concrete 400mm podium 20mm please make cable entrance hole in 8 2 2 Cable Pre embedded cab...

Страница 15: ...ion dry and solid make 8x installation hole in ground by M16 drill M16 8 4 Lift product Use crane or other tool to lift up product to the concrete and align to installation hole in concrete make sure...

Страница 16: ...Hisense B2B 1 Step 1 Install 4 eyebolt Step 2 After installation remove 4 eyebolts and replace it with rubber plug Step 3 Anchoring by dynabolt dynabolt Dynabolt into concrete Cross like this...

Страница 17: ...ll be implemented under the guidance of professional electrical engineer with multi meter 9 2 Power on procedure 9 2 1 External power supply Make sure voltage of power supply is compatible with the pr...

Страница 18: ...The product with air conditioner cooling when inside temperature up to a certain degree the A C will start working please clean the mesh in air vent after long time running 11 Media player Android me...

Отзывы: