Operator’s Manual
PRS 80
20
5.6
Angle
5.6.1 Operation
When an angle sensor is installed either with radio or hardwired the function of the console is the
same. The angle is displayed in tenths of a degree. When other sensors are installed, they can be
shown on other screens. These screens can be accessed with the up down arrows.
5.6.2 Limits
The limits are set by selecting
SETUP/ LIMITS/ ANGLE
There is then the choice to set the minimum angle limit or the maximum angle limit.
To set the limit:
•
Select the desired limit to set.
•
Move the boom to desired angle.
•
Press
enter.
The angle limits can be cleared without moving the boom to the desired angle. To clear the angle limit
without booming to the angle:
SETUP/ LIMITS/ ANGLE/MINIMUM
Press and hold the down arrow,
. The limits will change to -5 degrees.
SETUP/ LIMITS/ ANGLE/MAXIMUM
Press and hold the up arrow,
. The limits will change to 90 degrees.
© Hirschmann PRS80 REV. C 09/26/05