9.4 Event counter on port level
143
9.4 Event counter on port level
The port statistics table allows experienced network administrators to identify
possible problems occuring in the network.
This table shows you the contents of various event counters. After a restart,
all the event counters begin again at zero. The counters add up the events
transmitted and the events received.
Counter
Possible Problems
Received Fragments
– The controller of the connected device is faulty.
– Electromagnetic interference is injected into transfer medium.
CRC error
– The controller of the connected device is faulty.
– Electromagnetic interference is injected into transfer medium -
there is a faulty component in the network.
Collisions
– The controller of the connected device is faulty.
– The network expansion is too big or the line is too long.
– A packet has collided with an intererence signal.
Table 11: Examples indicating possible problems
V
Select the
Diagnostics:Ports:Statistics
dialog.
V
For reseting port counters select “Reset port counters” in the
Ba-
sics:Restart
dialog.
Содержание MS30, Power MICE, MACH 4000, OCTOPUS
Страница 8: ...Contents 8 Layer 2 Enhanced with Layer 2 Professional Release 1 0 10 05...
Страница 10: ...About this Manual 10 Layer 2 Enhanced with Layer 2 Professional Release 1 0 10 05...
Страница 14: ...Introduction 14 Layer 2 Enhanced with Layer 2 Professional Release 1 0 10 05...
Страница 177: ...General Information Layer 2 Enhanced with Layer 2 Professional Release 1 0 10 05 171 Appendix B General Information...
Страница 194: ...188 Index Layer 2 Enhanced with Layer 2 Professional Release 1 0 10 05...
Страница 195: ......
Страница 196: ......