MS20/MS30 MS20/MS30
Release 10 07/2012
7
CONTROL DRAWING
IRU,QGXVWULDO(7+(51(75DLO6ZLWFK06DQG06GHYLFHV
943-435-999
according to the directive 94/9/EC
or Class 1 Division 2 Hazardous Locations
Version: 1
Document No.: 000160011DNR
Page 1/4
5A
P1
P2
2UGLQDU\/RFDWLRQ
1RQ+D]DUGRXV$UHD
QRQH[SORVLYHDWPRVSKHUH
WARNING! The USB connection and the V.24
Interface connection are for temporary
connection only, for maintenance use. Do not
use, connect or disconnect unless the area is
known to be non-hazardous. Connection or
disconnection in an explosive atmosphere could
result in an explosion!
Relay
Relay
The earth conductor must be at
least the same wire size (mm²
or AWG) as the supply
conductors.
Power Supply range “C” (P1, P2 Redundant)
18 – 60 VDC;
4.0 – 1.2 A; max. 72 W
Relay contacts:
Equipment with nonincendive field wiring
parameters.
Polarity is not relevant.
THE RELAY TERMINALS ARE DEPENDENT
UPON THE FOLLOWING ENTITY
PARAMETERS:
1
)
2
)
Temperature Code: T4
Ambient Temperature rating:
Ta: 0 °C to +60 °C for “S” types
Ta: -40 °C to +70 °C for “T” or “E” types
²UHIHUWRWKHW\SHGHVLJQDWLRQRQWKHGHYLFH
3RVLWLRQRIQRPHQFODWXUH´7HPSHUDWXUHUDQJHµ
MS20/30 switch basic module
with voltage range type “C”
=RQH([SORVLYH$WPRVSKHUH
RU&ODVV'LYLVLRQ
*URXSV$%&'
+D]DUGRXV/RFDWLRQ
U
i
I
i
C
i
L
i
30 V
90 mA
2 nF
1 µH