Commissioning
4.3.4 Zero point adjustment of inclination sensor (X/Y) on
superstructure
Crane fully outriggered.
Preconditions:
Calling up function
from adjustment menu.
1)
Rotate main boom to travel direction and set down.
Confirm with
key when completed.
2)
Align crane precisely with spirit level in X and Y
direction.
The bubble might not be in the centre because the
sensor has not yet been adjusted.
Confirm with
key when completed.
Zero point is re-adjusted.
3)
The signal prefix is checked in the X direction. To do this:
Tilt the crane by at least 3° by raising the front
supports and/or lowering the rear supports.
Confirm with
key when completed.
4)
The signal prefix is checked in the Y direction. To do this:
Tilt the crane by at least 3° by raising the left-hand
supports and/or lowering the right-hand supports.
Confirm with
key when completed.
The signal prefix is automatically corrected.
5)
Align the crane once more precisely with a spirit level
in the X and Y direction. The bubble should now be
central.
Confirm next with
key.
Adjustment menu appears.
Select next sensor for adjustment as required.
© 2012 Hirschmann Automation and Control GmbH · Mobile Machine Control Solutions · www.hirschmann.com
29
/59
50-700-19-2001_422175_en (Manitex)_Rev_B.doc / 2012-03-13 / Issue B / rk.